English
Language : 

SP270-25-256-0 Datasheet, PDF (2/2 Pages) Infineon Technologies AG – General Sensor for Pressure Monitoring Systems (PMS)
Product Brief
SP27
General Sensor for Pressure Monitoring Systems (PMS)
Parameter
Symbol
Values
Unit
Min.
Max.
Input Pressure Range
Pin
100
500
kPa
Measurement Error
pError
-21
+21
kPa
pError
-46
+46
kPa
Input Pressure Range
pin
500
1300
kPa
Measurement Error
pError
-31
+31
kPa
pError
-60
+60
kPa
Temperature Measurement Error TError
-3
+3
°C
TError
-5
+5
°C
Tighter specifications are available on request.
Note/Test Condition
T = -40 ... 125°C
T = 25 ... 80°C
T = -40 ... 125°C
T = -40 ... 125°C
T = 25 ... 80°C
T = -40 ... 125°C
T = -20 ... 70°C
T = -40 ... -20°C
T = 70 ... 125°C
Product Summary
Sales Name
SP270-25-256-0
1) available under NDA
Description
Pressure sensor for various automotive and non-automotive
Pressure Monitoring Systems
Order Code
SP0009217821)
Published by
Infineon Technologies AG
85579 Neubiberg, Germany
© 2013 Infineon Technologies AG.
All Rights Reserved.
Visit us:
www.infineon.com
Order Number: B142-H9774-X-X-7600
Date: 01 / 2013
Attention please!
The information given in this document shall in no event
be regarded as a guarantee of conditions or characteristics
(“Beschaffenheitsgarantie”). With respect to any examples
or hints given herein, any typical values stated herein and/
or any information regarding the application of the device,
Infineon Technologies hereby disclaims any and all warran-
ties and liabilities of any kind, including without limita-
tion warranties of non-infringement of intellectual property
rights of any third party.
Information
For further information on technology, delivery terms and
conditions and prices please contact your nearest Infineon
Technologies Office (www.infineon.com).
Warnings
Due to technical requirements components may contain
dangerous substances. For information on the types in
question please contact your nearest Infineon Technologies
Office. Infineon Technologies Components may only be
used in life-support devices or systems with the express
written approval of Infineon Technologies, if a failure of
such components can reasonably be expected to cause
the failure of that life-support device or system, or to affect
the safety or effectiveness of that device or system. Life
support devices or systems are intended to be implanted
in the human body, or to support and/or maintain and
sustain and/or protect human life. If they fail, it is reason-
able to assume that the health of the user or other persons
may be endangered.