English
Language : 

TLE7189F Datasheet, PDF (19/29 Pages) Infineon Technologies AG – 3-Phase Bridge Driver IC
TLE7189F
Error condition
restart behavior
Shuts down...
Over temperature warning Self clearing
Nothing
VCC check
Latch, reset must be performed at ENA pin All external Power -MOSFETs
Note: All errors do NOT lead to sleep mode. Sleep mode is only initiated with the INH pin. The latch and restart
behavior allows to distinguish between the different error types combined at the ERR signals.
Table 4 Priorisation of Errors
Priority
1
2
3
4
5
Error
VCC check
Short circuit detection
Under voltage detection
Over voltage detection
Over temperature
Reset of ERROR registers and Disable
The TLE7189F can be reset with the help of the enable pin ENA. If the ENA pin is pulled to low for a specified
minimum time, the error registers are cleared and the external MOSFETs are switched off actively.
During disable only the errors under voltage shut down and over temperature warning are shown. Other errors are
not displayed.
5.2.8 Electrical Characteristics
Electrical Characteristics - Protection and diagnostic functions
VS = 5.5 to 20V, Tj = -40 to +150 °C, all voltages with respect to ground, positive current flowing into pin
(unless otherwise specified)
Pos. Parameter
Symbol
Limit Values
Unit Conditions
Min. Typ. Max.
Over temperature
5.2.1 Over temperature warning
Tj(OW)
135 155 175 °C
–
5.2.2 Hysteresis for over temperature dTj(OW) –
20
warning
Short circuit detection
5.2.3 Filter time of short circuit protection tSCP(off) 8
12
5.2.4 Maximum duty cycle for no SCD1) DSCDmax –
–
5.2.5 minimum duty cycle for periodic DSCDmin 70
–
SCD1)
5.2.6
5.2.7
Voltage range on VSCD pin to
adjust the Vds limit
Short circuit detection level
VSCDLa1 0.7
–
VSCDLa2 2.64
–
–
°C –
16
µs
30
%
–
%
2.5
V
3.63 V
Default
fPWM=100kHz at IHx
or ILx and at static
applied SC
fPWM=100 kHz at
IHx or ILx and at
static applied SC
Short circuit
detection is active
Short circuit
detection is active
VSCDL=3.3V
Data Sheet
19
Rev. 2.1, 2007-05-30