TLE4998P8D Grade1
Electrical, Thermal and Magnetic Parameters
Supply Undervoltage Range
Table 5-3
Electrical and Magnetic Characteristics in Supply Undervoltage Range1)
Parameter
Symbol
Values
Unit
Note / Test Condition
Min. Typ. Max.
Sensitivity drift
SE(T)
–
–
+2.5/-7.5 %
Sensitivity error over
lifetime2)
SE(L)
±1.8
%
Error band
at 25°C
Magnetic offset drift
∆BOS
–
–
±400 μT
Error band
Integral nonlinearity
INL
–
–
±0.2
%MFR Error band
Output noise (rms)
OUTnoise –
–
37.5
LSB12
50mT range, LP=1.39kHz,
Gain=1.5, B=0mT
1) The operation in supply undervoltage range is not intended for continuous operation, it has to be understood as an
extraordinary operation condition in order to cover the needs in safety relevant applications
2) Measurement condition at ±100 mT range
Overall Accuracy
Overall accuracy covers different sources of error within the operating temperature range, including the following:
• Temperature: Output deviation over the specified temperature range
• Aging: Parameter drift over life time
For the determination of the overall accuracy of the sensor with regard to specific application operation condition
the method of statistical sum of different sources of error can be used:
Overall error = sqrt(BOS2+TC2+SE(L)2+Inl2+OUTnoise2)
Abbreviations:
• BOS: Magnetic offset error
• TC: Temperature coefficient of sensitivity
• SE: Sensitivity error over lifetime
• Inl: Integral nonlinearity
• OUTnoise: output noise
5.1
Magnetic Field Direction Definition
Figure 5-2 shows the definition of the magnetic field direction. By standard the south pole field defines the positive
field values of the top die of TLE4998P8D.
N
Top Die S
Branded Side
Figure 5-2
Bottom Die
Definition of magnetic field direction of the PG-TDSO-8-2