Local Failure-Flags and -Detection
TxD Dominant Failure Detection
• Effect: permanent dominant signal for t > tTxD at TxD
• Indicator: NERR = LOW in RxOnly mode (local failure flag is set)
• Action: disabling of the transmitter stage
• Remarks: release of the transmitter stage only after transition into RxOnly mode (failure
diagnosis) and transition into normal mode.
RxD Permanent Recessive Clamping
• Effect: internal RxD signal does not match signal at RxD pin because the RxD pin is pulled
to HIGH (permanent HIGH)
• Indicator: NERR = LOW in RxOnly mode (local failure flag is set)
• Action: disabling of the receiver stage
• Remarks: the flag is cleared by changing from RxOnly (failure diagnosis) into normal mode
or RxD gets dominant.
TxD to RxD Short Circuit
• Effect: short circuit between RxD and TxD
• Indicator: NERR = LOW in RxOnly mode (local failure flag is set)
• Action: disabling of the transmitter stage
• Remarks: the flag is cleared by changing from RxOnly (failure diagnosis) into normal mode.
Bus Dominant Clamping
• Effect: permanent dominant signal at the CAN bus for t > tBUS
• Indicator: NERR = LOW in RxOnly mode (local failure flag is set)
• Action: none
• Remarks: none
Overtemperature Detection
• Effect: junction temperature at the driving stages exceeded
• Indicator: NERR = LOW in RxOnly mode (local failure flag is set)
• Action: disabling of the transmitter stage
• Remarks: the flag is cleared by changing from RxOnly (failure diagnosis) into normal mode
or RxD gets dominant. Bus only released after the next dominant bit in TxD.