ICE3BS03LJG Datasheet, PDF (15/25 Pages) Infineon Technologies AG – Off-Line SMPS Current Mode Controller with integrated 500V Startup Cell
F3 PWM controller
ICE3BS03LJG
Functional Description
3.7.2.1 Entering Active Burst Mode
The FB signal is kept monitoring by the comparator C4.
During normal operation, the internal blanking time
counter is reset to 0. When FB signal falls below 1.23V,
VFB
it starts to count. When the counter reach 20ms and FB
signal is still below 1.23V, the system enters the Active 4.0V
Entering
Active Burst
Mode
Leaving
Active Burst
Mode
Burst Mode. This time window prevents a sudden 3.5V
entering into the Active Burst Mode due to large load 3.0V
jumps.
After entering Active Burst Mode, a burst flag is set and 1.23V
the internal bias is switched off in order to reduce the
current consumption of the IC to approx. 450uA.
Blanking Timer
t
It needs the application to enforce the VCC voltage
20ms Blanking Time
above the Undervoltage Lockout level of 10.5V such
that the Startup Cell will not be switched on
accidentally. Or otherwise the power loss will increase
drastically. The minimum VCC level during Active Burst
Mode depends on the load condition and the
application. The lowest VCC level is reached at no load
condition.
VCS
t
3.7.2.2 Working in Active Burst Mode
After entering the Active Burst Mode, the FB voltage
rises as VOUT starts to decrease, which is due to the
inactive PWM section. The comparator C6a monitors
the FB signal. If the voltage level is larger than 3.5V, the
internal circuit will be activated; the Internal Bias circuit
1.06V
0.25V
Current limit level
during Active Burst
Mode
resumes and starts to provide switching pulse. In
Active Burst Mode the gate G10 is released and the VVCC
t
current limit is reduced to 0.25V. In one hand, it can
reduce the conduction loss and the other hand, it can
reduce the audible noise. If the load at VOUT is still kept
unchanged, the FB signal will drop to 3.0V. At this level
the C6b deactivates the internal circuit again by
switching off the internal Bias. The gate G11 is active
again as the burst flag is set after entering Active Burst
10.5V
Mode. In Active Burst Mode, the FB voltage is changing
like a saw tooth between 3.0V and 3.5V (see Figure
IVCC
t
24).
3.7.2.3 Leaving Active Burst Mode
2.5mA
The FB voltage will increase immediately if there is a
high load jump. This is observed by the comparator C4.
As the current limit is app. 25% during Active Burst 450uA
Mode, a certain load jump is needed so that the FB
signal can exceed 4.0V. At that time the comparator C4 VOUT
t
resets the Active Burst Mode control which in turn
blocks the comparator C12 by the gate G10. The
maximum current can then be resumed to stabilize
VOUT.
Version 2.0
t
Figure 24 Signals in Active Burst Mode
15
6 Dec 2007