CCM-PFC
ICE2PCS04/G
Electrical Characteristics
4.3
Note:
4.3.1
Characteristics
The electrical characteristics involve the spread of values within the specified supply voltage and junction
temperature range TJ from – 40 °C to 125°C.Typical values represent the median values, which are
related to 25°C. If not otherwise stated, a supply voltage of VCC =18V is assumed for test condition.
Supply Section
Parameter
VCC Turn-On Threshold
VCC Turn-Off Threshold/
Under Voltage Lock Out
VCC Turn-On/Off Hysteresis
Start Up Current
Before VCCon
Operating Current with active GATE
Operating Current during Standby
Symbol
VCCon
Limit Values
min. typ. max.
11.4 11.8 12.7
Unit Test Condition
V
VCCUVLO 10.4 11.0 11.7 V
VCChy
0.65 0.8 1.4 V
ICCstart
-
450 1100 mA VVCC=VVCCon -0.1V
ICCHG
-
10 20 mA CL= 4.7nF
ICCStdby
-
700 1300 mA VVSENSE= 0.5V
VICOMP= 4V
4.3.2 PWM Section
Parameter
Fixed Oscillator Frequency
Max. Duty Cycle
Min. Duty Cycle
Min. Off Time
Symbol
fSW
Limit Values
min. typ. max.
118 133 138
Unit Test Condition
kHz
DMAX
92
95
98.5 %
DMIN
TOFFMIN 150
400
0
650
%
VVCOMP= 0V, VVSENSE= 3V
VICOMP= 4.3V
ns
VVSENSE= 3V
VISENSE= 0.1V
Version 2.0