4.3.3
Input voltage sense
Parameter
Symbol
Input voltage on threshold
Bias current on VINS pin
Blankint time for leaving mains
undervoltage protection
VVINSon
Ihys
TVINS_out
Blanking time for entering
TVINS_in
mains under voltage protection
Half-Bridge Resonant Controller
ICE1HS01G
Electrical Characteristics
Limit Values
Unit
min. typ.
max.
1.2
1.25 1.3
V
9
12
15
µA
500
µs
50
µs
Test Condition
4.3.4
Current sense
Parameter
Overcurrent protection low
Hysteresis voltage for
overcurrent protection low
Symbol
VCSL
Limit Values
Unit
min. typ.
max.
0.75 0.8
0.85 V
50
mV
Test Condition
Overcurrent protection high
Blanking time for OCP latch
Maximum switching frequency
during over current protection
VCSH
TOCP_L
FMAX_C
Counter input voltage high
VCS_CH
Counter input voltage low level VCS_CL
Blanking time after each gate is TLEB
turned on
1.57 1.63 1.7
_
300
_
163
4.5
0.5
250
V
ns
kHz
RFMIN=30kΩ; VFB=4.2V,
VCS=1V, after soft start
and 2ms after VCS
higher than 0.8V
V
Not subject to test
V
Not subject to test
ns
Version 2.0
14