English
Language : 

TLE4997E2 Datasheet, PDF (13/35 Pages) Infineon Technologies AG – Programmable Linear Hall Sensor
TLE4997
Operating Range
4
Operating Range
The following operating conditions must not be exceeded in order to ensure correct
operation of the TLE4997. All parameters specified in the following sections of this
document refer to these operating conditions, unless otherwise indicated.
Table 3
Operating Range
Parameter
Symbol Limit Values
min. max.
Supply voltage
VDD
4.5 5.5
4
7
Output current
Load resistance
IOUT
-1
1
RL
10 -
10 -
Load capacitance
CL
Junction temperature 3) TJ
0
210
-40 125
150
Useful lifetime
tLive
-
16
1) For reduced output accuracy.
2) For VOUT within the range of 5% ... 95% of VDD.
3) RTHja ≤ 150 K/W.
4) For reduced magnetic accuracy.
5) Not additive.
Unit Notes
V
V
mA
kΩ
nF
°C
years
Extended range 1)
2)
Pull-down to GND
Pull-up to VDD
For 5000h
For 1000h4) 5)
Note: Keeping signal levels within the limits specified in this table ensures operation
without overload conditions.
Data Sheet
13