English
Language : 

ICE3B0365JG Datasheet, PDF (13/22 Pages) Infineon Technologies AG – Off-Line SMPS Current Mode Controller with integrated 650V Startup Cell/Depletion CoolMOS
CoolSET™-F3
ICE3B0365JG/ICE3B0565JG
blocks C12 by the gate G10. Maximum current can now
be provided to stabilize VOUT.
VFB
4.5V
3.61V
3.0V
Entering
Active Burst
Mode
Leaving
Active Burst
Mode
1.35V
VSoftS
t
Blanking Window
4.0V
3.6V~
3.2V
3.0V
3.6.3
Protection Modes
The IC provides several protection features that
increase the SMPS system’s robustness and safety.
The following table shows the possible system failures
and the corresponding protection modes.
VCC Overvoltage
Over temperature
Overload
Open Loop
VCC Undervoltage
Short Optocoupler
Auto Restart Mode I
Auto Restart Mode I
Auto Restart Mode II
Auto Restart Mode II
Auto Restart Mode II
Auto Restart Mode II
3.6.3.1 Auto Restart Mode I
VCS
1.0V
0.32V
Current limit level
during Active Burst
Mode
VVCC
10.3V
IVCC
2mA
500uA
VOUT
Max. Ripple < 1%
t
SoftS
C3
4.0V
t
S
&
RQ
UVLO FF2
G13
VCC
C13
&
t
20.5V
Auto
Restart
Mode
Spike
Blanking
8.0us
C4
4.5V
G12
Thermal Shutdown
Internal
Bias
t
Tj >140°C
Control Unit
FB
Figure 15 Signals in Active Burst Mode
Figure 16 Auto Restart Mode I
The VCC voltage is observed by comparator C13 if
20.5V is exceeded. The output of C13 is combined with
t
both the output of C3 which checks for VSoftS < 4.0V and
the output of C4 which checks for VFB > 4.5V. Therefore
the overvoltage detection can only be active during Soft
Start Phase (VSoftS < 4.0V) and when FB signal is
outside the operating range > 4.5V. This means any
Version 2.0
13
14 Nov 2006