English
Language : 

IGCM06F60GA_16 Datasheet, PDF (12/17 Pages) Infineon Technologies AG – Control Integrated POwer System
Control Integrated POwer System (CIPOS™)
IGCM06F60GA
Circuit of a Typical Application
#4
#1
Micro
Controller
VDD line
5 or 3.3V line
#3
Temperature monitor
#2
<Signal for protection>
Figure 9 Typical application circuit
(1) VS(U)
(2) VB(U)
(3) VS(V)
(4) VB(V)
(5) VS(W)
(6) VB(W)
VB1
RBS1
VB2
RBS2
VB3
RBS3
HO1
VS1
HO2
VS2
HO3
VS3
(7) HIN(U)
HIN1
LO1
(8) HIN(V)
HIN2
(9) HIN(W)
(10) LIN(U)
HIN3
LIN1
(11) LIN(V)
LIN2
LO2
(12) LIN(W)
LIN3
(13) VDD
VDD
(14) VFO
VFO
(15) ITRIP
LO3
ITRIP
(16) VSS
VSS
Thermistor
U-phase current sensing
V-phase current sensing
W-phase current sensing
<Signal for protection>
NC (24)
P (23)
U (22)
V (21)
3-ph AC
Motor
W (20)
#5
NU (19)
#6
NV (18)
NW (17)
#7
Power
GND line
1. Input circuit
- To reduce input signal noise by high speed switching, the RIN and CIN filter circuit should be mounted. (100Ω, 1nF)
- CIN should be placed as close to VSS pin as possible.
2. Itrip circuit
- To prevent protection function errors, CITRIP should be placed as close to Itrip and VSS pins as possible.
3. VFO circuit
- VFO output is an open drain output. This signal line should be pulled up to the positive side of the 5V/3.3V logic
power supply with a proper resistor RPU.
- It is recommended that RC filter be placed as close to the controller as possible.
4. VB-VS circuit
- Capacitor for high side floating supply voltage should be placed as close to VB and VS pins as possible.
5. Snubber capacitor
- The wiring between CIPOS™ Mini and snubber capacitor including shunt resistor should be as short as possible.
6. Shunt resistor
- The shunt resistor of SMD type should be used for reducing its stray inductance.
7. Ground pattern
- Ground pattern should be separated at only one point of shunt resistor as short as possible.
Datasheet
12
<Revision 2.7>
<2016-08-01>