SAA-XC886CLM
Electrical Parameters
4.1.3 Operating Conditions
The following operating conditions must not be exceeded in order to ensure correct
operation of the SAA-XC886. All parameters mentioned in the following table refer to
these operating conditions, unless otherwise noted.
Table 37 Operating Condition Parameters
Parameter
Symbol
Limit Values
min.
max.
Unit Notes/
Conditions
Digital power supply voltage VDDP
4.5
5.5
V 5V Device
Digital ground voltage
VSS
0
V
Digital core supply voltage VDDC
2.3
2.7
V
System Clock Frequency1) fSYS
88.8
103.2 MHz
Ambient temperature
TA
-40
140
°C SAA-XC886...
1) fSYS is the PLL output clock. During normal operating mode, CPU clock is fSYS / 4. Please refer to Figure 25
for detailed description.