4.2
Functional Range
BTS5012-1EKB
General Product Characteristics
Table 3 Functional Range TJ = -40 °C to +150 °C; (unless otherwise specified)
Parameter
Symbol
Values
Unit Note /
Min. Typ. Max.
Test Condition
Nominal operating voltage VNOM
8
13.5 18
V
–
Extended operating voltage VS(OP)
5
–
28
V
2) VIN = 4.5 V
RL = 2 Ω
VDS < 0.5 V
See Figure 15
Minimum functional supply VS(OP)_MIN 3.8
4.2
5
voltage
V
1) VIN = 4.5 V
RL = 2 Ω
From IOUT = 0 A
to
VDS < 0.5 V;
See Figure 15
Undervoltage shutdown
VS(UV)
3
3.4
4.1
V
1) VIN = 4.5 V
VDEN = 0 V
RL = 2 Ω
From VDS < 1 V;
to IOUT = 0 A
See Figure 15
See Figure 30
Undervoltage shutdown
hysteresis
VS(UV)_HYS –
850 –
mV 2) –
Operating current channel IGND_1
–
5
9
mA VIN = 5.5 V
active
VDEN = 5.5 V
Device in RDS(ON)
VS = 18 V
See Figure 31
Standby current for whole IS(OFF)
–
0.1
0.9
μA
1) VS = 18 V
device with load (ambiente)
VOUT = 0 V
VIN floating
VDEN floating
TJ ≤ 85 °C
See Figure 32
Maximum standby current for IS(OFF)_150 –
4
34
μA VS = 18 V
whole device with load
VOUT = 0 V
VIN floating
VDEN floating
TJ = 150 °C
See Figure 32
Standby current for whole
IS(OFF_DEN) –
device with load, diagnostic
active
1) Test at TJ = -40°C only
0.6 –
mA 2) VS = 18 V
VOUT = 0 V
VIN floating
VDEN = 5.5 V
Number
P_4.2.1
P_4.2.2
P_4.2.3
P_4.2.4
P_4.2.13
P_4.2.5
P_4.2.7
P_4.2.10
P_4.2.8
Data Sheet
PROFET™+ 12V