PEF81912 Datasheet, PDF (100/276 Pages) Infineon Technologies AG – Q-SMINT®IX 2B1Q Second Gen. Modular ISDN NT (Intelligent eXtended) | |||
|
◁ |
PEF 81912/81913
DC: Deactivation Confirmation
DI: Deactivation Indication
DR: Deactivation Request
DT: Data Through test mode
EI1: Error Indication 1
PU: Power-Up
RES: Reset
SSP: Send Single Pulses test mode
TIM: Timing request
Functional Description
2.4.10 State Machines for Line Activation / Deactivation
2.4.10.1 Notation
The state machines control the sequence of signals at the U-interface that are generated
during the start-up procedure. The informations contained in the following state diagrams
are:
â State name
â U-signal transmitted
â Overhead bits transmitted
â C/I-code transmitted
â Transition criteria
â Timers
Figure 45 shows how to interpret the state diagrams.
â¢
IN
Signal Transmitted
to U-Interface
(general)
Single Bit
Transmitted
to U-Interface
State Name
Indication Transmitted on C/I-Channel
(DOUT)
ITD04257.vsd
OUT
Figure 45 Explanation of State Diagram Notation
Data Sheet
84