English
Language : 

TLE7186F Datasheet, PDF (10/39 Pages) Infineon Technologies AG – System IC for B6 motor drives
TLE7186F
General Product Characteristics
Absolute Maximum Ratings (cont’d)1)
Tj = -40 °C to +150 °C; all voltages with respect to ground, positive current flowing into pin (unless otherwise
specified)
Pos.
Parameter
Symbol
Limit Values Unit Conditions
Min.
Max.
4.1.26
4.1.27
Storage temperature
Case temperature2)
Tstg
-55
150
TCase
–
145
ESD Susceptibility
4.1.28 ESD Resistivity3)
VESD
-2
+2
4.1.29 CDM
VCDM
–
500
1) Not subject to production test, specified by design.
2) Calculation based on Tjmax, RthJC and the assumption of 1W power dissipation
3) ESD susceptibility HBM according to EIA/JESD 22-A 114B
°C –
°C –
kV –
V–
Note: Stresses above the ones listed here may cause permanent damage to the device. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Note: Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as “outside” normal operating range. Protection functions are
not designed for continuous repetitive operation.
4.2
Functional Range
Pos. Parameter
4.2.1 Supply voltage at VS
4.2.2
Quiescent current
(IVS + IVDH + IIFMA)
4.2.3 Supply current at VS (device
enabled)
Symbol
VVS
Limit Values
Min.
Max.
6.0
45
IQ
–
50
IVS(0)
–
19
Unit Conditions
V
below 7V reduced
functionality1) 2)
µA
VS<16V;
sleep mode
VVS=VVDH=VIFMA
mA Vs=8...18V;
no load3);
fPWM=25kHz;
4.2.4
4.2.5
Duty cycle HS
Duty cycle LS
DHS
0
94
DLS
0
100
4.2.6 Junction temperature
TJ
-40
150
1) MOS driver output deactivated and ERROR pin set to low if VREG is lower UVVR
2) MOS driver output stage will operate at Vs=6.7V with 5mA load current at VREG
3) no load at VDD, ERR, ISO, IFµC, VDHS, GXX, TEMP, DT
%
fPWM=25kHz;
%
continuous
operation
°C
–
The limitations in the PWM frequency are given by thermal constraints and limitations in the duty cycle (charging
time of bootstrap capacitor).
All maximum ratings have to be considered
All basic functions will work between TJ=150°C and Over Temperature shut down. In this temperature range, the
parameters might leave the specified range.
Data Sheet
10
Rev. 1.2, 2016-01-28