English
Language : 

TLE4966L_09 Datasheet, PDF (10/16 Pages) Infineon Technologies AG – High Precision Hall-Effect Switch with Direction Detection
TLE4966L
Electrical and Magnetic Parameters
5
Electrical and Magnetic Parameters
Table 5
Electrical Characteristics 1)
Parameter
Symbol Limit Values Unit Conditions
min. typ. max.
Supply current
Reverse current
Output saturation
voltage
IS
4
ISR
0
VQSAT –
5.2 7
mA VS = 2.7 V ... 18 V
0.2 1
mA VS = -18 V
0.3 0.6 V
IQ = 10 mA
Output leakage
current
IQLEAK –
0.05 10 µA for VQ = 18 V
Output fall time
tf
Output rise time
tr
–
0.2 1
µs RL = 1.2 kΩ; CL < 50 pF
–
0.2 1
µs see:
Figure 3 on Page 12
Chopper frequency fOSC
Switching frequency fSW
Delay time 3)
td
Count Signal Delay tdc
Output jitter 4)
tQJ
–
320 –
kHz
0
–
15 2) kHz
–
13 –
µs
50 200 1000 ns
–
1
–
µsRMS Typ. value for square-
wave signal 1 kHz
Repeatability of
BREP
–
magnetic thresholds 5)
40 –
µTRMS Typ. value for
∆B/∆t > 12 mT/ms
Power-on time 6)
tPON
–
13 –
µs VS ≥ 2.7 V
Distance of hall plates dHALL –
Thermal resistance 7) RthJA
–-
1.45 –
mm
-
–190 K/W PG-SSO-4-1
1) over operating range, unless otherwise specified. Typical values correspond to VS = 12 V and TA = 25°C
2) To operate the sensor at the max. switching frequency, the magnetic signal amplitude must be 1.4 times
higher than for static fields. This is due to the -3 dB corner frequency of the low pass filter in the signal path.
3) Systematic delay between magnetic threshold reached and output switching
4) Jitter is the unpredictable deviation of the output switching delay
5) BREP is equivalent to the noise constant
6) Time from applying VS ≥ 2.7 V to the sensor until the output state is valid
7) Thermal resistance from junction to ambient
Data Sheet
10
V 2.0, 2009-02