English
Language : 

KP125 Datasheet, PDF (10/24 Pages) Infineon Technologies AG – Absolute Pressure Sensor
5
Electrical Characteristics
5.1
Absolute Maximum Ratings
Pressure Sensor
KP125
Electrical Characteristics
Table 3 Absolute Maximum Ratings
Parameter
Symbol
Min.
Supply voltage
VDD
– 0.3
–
– 6.5 1)
Output voltage
Maximum ambient
temperature
VOUT
TA
– 0.3
– 40
Storage temperature
Maximum input pressure
range
TS
PMAX
– 60
40
5.8
40
5.8
Voltage at CLOCK / VPROG Pin VCLK
–
Voltage at data pins
(DATA IN, DATA OUT)
VDATA
–
ESD robustness 2)
VESD, HBM –
Values
Typ.
–
–
–
–
Unit
Max.
6.5
V
16.5
–
VDD+ 0.3 V
125
°C
150
°C
–
600
kPa
87
psi
–
150
kPa
21.75 psi
–
20
V
–
5.0
V
–
±2
kV
–
–
±2
kV
1) Reverse polarity; IDD < 300mA
2) HBM: 1.5kΩ, 100pF; according to EIA/JESD22-A114-B (covers MIL STD 883D)
Note / Test Condition
1h @ 70°C
for max. 5 minutes
for max. 5 minutes
Analog pins:
VDD, Vout, GND
Digital pins:
CLOCK / VPROG,
DATA OUT,
DATA IN
Attention: Stresses above the max. values listed here may cause permanent damage to the device.
Exposure to absolute maximum rating conditions for extended periods may affect device
reliability. Maximum ratings are absolute ratings; exceeding only one of these values may
cause irreversible damage to the integrated circuit.
Data Sheet
10
Rev 2.14, 2007-11-23