English
Language : 

ILD2111 Datasheet, PDF (10/66 Pages) Infineon Technologies AG – Digital DC/DC Buck Controller IC
ILD2111
Functional Description
Operating statuses are presented in Table 3-1 below.
Table 3-1. Device Operating Statuses
Status
Value Description
OPER_STATUS
ERR_STATUS
ERR_MODE
OPER_OFF
OPER_STARTUP
OPER_RUN
OPER_ERR
OPER_STOP
ERR_NONE
ERR_INPUV
ERR_INPOV
ERR_OUTUV
ERR_OUTOV
ERR_PWR
ERR_OPEN
ERR_OCP
ERR_OTI
ERR_OTE
ERR_PARAM_EMPTY
ERR_PARAM_DATA
ERR_MODE_LATCH
0000H
0001H
0002H
0004H
0008H
0000H
0001H
0002H
0004H
0008H
0010H
0020H
0040H
0080H
0100H
0400H
0800H
Off - initial buck state
Startup - Vin & temperature checking
Run
Stopped by error
Stopped by UART command
No errors
Input undervoltage
Input overvoltage
Output undervoltage
Output overvoltage
Output overpower
Output open
OCP2 level detection
Overtemperature internal sensor
Overtemperature external sensor
Default parameter block empty
Default parameter block checksum error
Error handling latch
ERR_MODE_RESTART
Error handling auto restart
ERR_MODE_OFF
Error handling is off
ERR_MODE_NOP
BUCK_STATUS 1) BUCK_OFF
Error handling does not affect auto restart counter
Buck is off
BUCK_STARTUP
Buck is in start-up phase (initialized, waiting for
start-up condition, i.e. voltage and temperature)
BUCK_SOFTSTART
Buck is in soft-start phase (implements increasing
current slope until reaching reference current)
BUCK_SHUTDOWN
Buck is in shutdown phase (implements current
decreasing slope)
BUCK_EXE_OFF
Buck is executing off, buck operation stopped
BUCK_ERRC
BUCK_ON 2)
Buck in error state (generate small error current)
Buck is on (normal operation, default state of
operation)
During normal operation, in addition to the
aforementioned operations, the following actions
will be executed:
− Open-output processing
− Output current PWM dimming processing
− VCC / internal temperature measurement and
processing
− External temperature measurement and
processing
− OCP1 - peak current processing
− OCP2 - peak current processing
− EPWM measurement and processing
− PI regulator processing
− Input over- and undervoltage processing
− Output over- and undervoltage processing
− Output overpower processing
1) See buck state machine in Figure 5.
2) The number of averaged buck cycles for steady-state operation, where calculations and protections are
handled, is defined by the constant Buck_steady_delay (see Table 3-14).
Datasheet