English
Language : 

BTM7741G Datasheet, PDF (10/18 Pages) Infineon Technologies AG – TrilithIC
BTM7741G
5
Electrical Characteristics
5.1
Absolute Maximum Ratings
Absolute Maximum Ratings1)
– 40 °C < Tj < 150 °C
Pos. Parameter
Symbol Limit Values
min. max.
High-Side-Switches (Pins DHVS, IH1,2 and SH1,2)
5.1.1
5.1.2
Supply voltage
Supply voltage for full short circuit
protection
VS
– 0.3 42
VS(SCP) –
28
5.1.3 HS-drain current2)
5.1.4 HS-input current
5.1.5 HS-input voltage
Status Output ST
IS
–7
3)
IIH
–5
5
VIH
– 10 16
5.1.6 Status pull up voltage
VST
– 0.3 5.4
5.1.7 Status Output current
IST
–5
5
5.1.8 Low-Side-Switches (Pins DL1,2, IL1,2 and SL1,2)
5.1.9 Drain-Source-Clamp voltage
VDSL
42
–
5.1.10 Supply voltage for short circuit protection VDSL(SCP) –
30
5.1.11
–
20
5.1.12 LS-drain current2)
5.1.13 LS-input voltage
Temperatures
IDL
–7
3)
VIL
– 0.3 10
5.1.14 Junction temperature
5.1.15 Storage temperature
ESD Protection4)
Tj
– 40 150
Tstg
– 55 150
5.1.16
5.1.17
5.1.18
5.1.19
Input LS-Switch
Input HS-Switch
Status HS-Switch
Output LS and HS-Switch
VESD
–
2
VESD
–
1
VESD
–
2
VESD
–
8
1) Not subject to production test; specified by design
2) Single pulse
3) Internally limited
4) ESD susceptibility HBM according to EIA/JESD22-A114-B (1.5kΩ, 100pF)
Unit Remarks
V–
V
A TA = 25°C; tP < 100 ms
mA Pin IH1 and IH2
V Pin IH1 and IH2
V
mA Pin ST
V VIL = 0 V; ID ≤ 1 mA
V VIL = 5 V
V VIL = 10 V
A TA = 25°C; tP < 100 ms
V–
°C –
°C –
kV
kV
kV
kV all other pins connected
to Ground
Note: Stresses above the ones listed here may cause permanent damage to the device. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Note: Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as “outside” normal operating range. Protection functions are
not designed for continuous repetitive operation.
Data Sheet
10
Rev. 1.0, 2007-05-21