English
Language : 

T1052S Datasheet, PDF (1/6 Pages) Infineon Technologies AG – Schneller Thyristor Fast Thyristor
S
Schneller Thyristor
Fast Thyristor
Datenblatt / Data sheet
T1052S
Elektrische Eigenschaften / Electrical properties
Höchstzulässige Werte / Maximum rated values
PerKiodeisncnhde aStpeitznensperrspannung
Tvj = -40°C... Tvj max
repeEtitivleepkeatkrreivsercsehvoeltageEs igenschaften
Stoßspitzensperrspannung
Tvj = +25°C... Tvj max
non-repetitive peak reverse voltage
Durchlaßstrom-Grenzeffektivwert
maximum RMS on-state current
Dauergrenzstrom
average on-state current
Dauergrenzstrom
average on-state current
Durchlaßstrom-Effektivwert
RMS on-state current
Stoßstrom-Grenzwert
surge current
TC = 85°C
TC = 55 °C, θ = 180°sin, tP = 10 ms
Tvj = 45°C, tP = 10 ms
Tvj = Tvj max , tP = 10 ms
Grenzlastintegral
I²t-value
Kritische Stromsteilheit
critical rate of rise of on-state current
Kritische Spannungssteilheit
critical rate of rise of off-state voltage
Tvj = 45°C, tP = 10 ms
Tvj = Tvj max , tP = 10 ms
DIN IEC 60747-6
vD ≤ 67%VDRM, f = 50 Hz,
iGM = 1,2 A, diG/dt = 1,2 A/µs
Tvj = Tvj max, vD = 0,67 VDRM
5.Kennbuchstabe / 5th letter
VDRM, VRRM
VRSM
ITRMSM
ITAVM
ITAVM
ITRMS
ITSM
I²t
(diT/dt)cr
(dvD/dt)cr 1)
C: 500
M: 1000
1200 V
1300 V
2200 A
1050 A
1510 A
2380 A
22,5 kA
20,0 kA
2,53 106A²s
2,00 106A²s
400 A/µs
2)
500 V/µs
500 V/µs
Charakteristische Werte / Characteristic values
Durchlaßspannung
on-state voltage
Tvj = Tvj max , iT = 4000A
vT
max.
2,7 V
Schleusenspannung
threshold voltage
Tvj = Tvj max
V(TO)
1,45 V
Ersatzwiderstand
slope resistance
Tvj = Tvj max
rT
0,3 mΩ
Durchlaßkennlinie 300 A ≤ iT ≤ 5000 A
on-state characteristic
v T = A + B ⋅ i T + C ⋅ ln ( i T + 1 ) + D ⋅ iT
Tvj = Tvj max
A=
1,892E+00
B=
6,402E-05
C=
-1,162E-01
D=
2,382E-02
Zündstrom
gate trigger current
Tvj = 25 °C, vD = 12V
IGT
max.
300 mA
Zündspannung
gate trigger voltage
Tvj = 25 °C, vD = 12V
VGT
max.
2,2 V
Nicht zündender Steuerstrom
gate non-trigger current
Tvj = Tvj max , vD = 12V
IGD
max.
20 mA
Nicht zündende Steuerspannung
gate non-trigger voltage
Tvj = Tvj max , vD = 0,5 VDRM
VGD
max. 0,25 V
Haltestrom
holding current
Tvj = 25°C, vD = 12V
IH
max.
250 mA
Einraststrom
latching current
Tvj = 25°C, vD = 12V, RGK ≥ 10 Ω
IL
iGM = 1,2 A, diG/dt = 1,2 A/µs,
tg = 20 µs
max. 1000 mA
1) Werte nach DIN IED 747-6 (ohne vorausgehende Kommutierung) / values to DIN IEC 747-6 (without prior commutation)
2) Unmittelbar nach der Freiwerdezeit, vgl. Meßbedingungen für tq / immediatley after circuit commutated turn-off time, see Parameters tq
prepared by: H.Sandmann
approved by: J.Przybilla
date of publication:
revision:
2008-09-15
3.0
IFBIP SDeAiteEC/ p, a2g0e08A-0194-/1952, H.Sandmann
A 42/08
Seite/page
1/6