9. About vibration.
A terminal blank, a terminal bend, and a crease may occur
by adding too much vibration to a capacitor. When there
becomes too much vibration, please contact our company.
10. When used on a double sided printed circuit board,
do not design exposed circuit board traces under the
super capacitor.
An electrical short could occur if the super capacitor
electrolyte should leak onto the circuit board.
11. Do not store in high temperature and high humidity
conditions.
Avoid high temperature or high humidity or direct rays
when storing capacitors. Avoid direct contact with water,
salt water or oil, toxic gases, or dusty environment.
12. When soldering the super capacitor to the wiring
board, do not attach the body of the super capacitor to
the circuit boards.
If the body of the capacitor is attached directly to the
circuit board, the flux or solder can blow through the
mounting holes in the circuit board, possibly causing
internal damage to the super capacitor.
13. Do not overheat when soldered.
Excessive heat may cause deterioration of the electrical
characteristics of the aerogel super capacitor, electrolyte
leakage or an increase in internal pressure.
14. Circuit board cleaning after soldering.
Circuit boards can be immersed or ultrasonically cleaned
using suitable cleaning solvents for up to 5 minutes and
up to 60˚C maximum temperatures. The boards should be
thoroughly rinsed and dried.
Wave solder
Temperature
(°C)
220
240
250
260
Exposure time (seconds)
Recommended
exposure time
7
7
5
3
Maximum
exposure time
9
9
7
5
15. Be careful not to apply an excessive force to the
capacitor body, terminals or lead wires.
If the capacitor body is subjected to stress such as
grabbing, falling, bend, pushing or twisting after mounted,
its terminals may come off, leading to open, short or liquid
leakage.
16. Emergency procedures.
If a super capacitor is found to be overheating or starts to
smell, immediately switch off the unit’s main power or load
to stop operation. Do not expose your face and hands if
exposed to electrolyte. Wash exposed area thoroughly
with soap and water.
®