English
Language : 

MHBS Datasheet, PDF (1/11 Pages) Illinois Capacitor, Inc. – Small size - High voltage – High Capacitance
FEATURES
Small size - High voltage – High Capacitance
APPLICATIONS
UPS – DC link – AC/DC motor controls – Power inverters
Operating Temperature Range
Capacitance Tolerance
Surge
Voltage
VDC
Repetitive
SVDC
Non-
repetitive
SVDC
Code
85°C
70°C
85°C
70°C
85°C
70°C
Code
AC Voltage
VDC
VAC
85°C
70°C
Dissipation Factor (MAX)
Tan δ (%)
at 1 kHz and 25°C
ESR
(mΩ)
RMS Current
Ripple Current
Insulation Resistance
Self Inductance
Long Term Stability
Dielectric Strength
-40°C to +100°C
Above +85°C applied voltage must be de-rated by 1.5%/°C
+10% at 1 kHz, 25°C
+5% optional
A35 A40
A45
A50 A55 A60
A70
575 700
800
900 1000 1100 1275
630 770
880
1000 1100 1200 1400
660 805
920
1035 1150 1265 1465
720 885 1010 1150 1265 1380 1610
750 910 1040 1170 1300 1430 1655
815 1000 1140 1300 1430 1560 1820
Repetitive SVDC: Maximum repetitive voltage for 1 hour Max/Day
A35 A40
A45
A50 A55 A60
A70
575 700
800
900 1000 1100 1275
240 285
315
350
400
420
440
250 300
330
370
420
440
460
C< 4μF 4μF<C<12μF 12μF<C<20μF 20μF<C<40μF 40μF<C<75μF C>75μF
.06
.08
.11
.14
.17
.2
Lead spacing
(mm)
Frequency range
ESR Value
27.5
10kHz - 60kHz
See standard part listing
37.5
10kHz – 45 kHz
See standard part listing
52.5
10kHz – 30 kHz
See standard part listing
No RMS current is to be applied at temperatures > +95°C
See standard part listing, No ripple current is to be applied when the ambient temperature
is>+95°C
3000 MΩxuF (10000 MΩxuF typical)
“Not to exceed 3GΩ”
After 1 minute of 100VDC applied between the terminals at 25°C
<1 nano-Henry per mm of lead spacing and lead length
Capacitance variation <1% MAX after 2 years
Terminal to Terminal
150% of VDC or 150% of VAC
applied for 10 Seconds and 25°C
Terminal to case
3KVAC at 50/60 Hz applied between the terminals
and case for 60 Seconds and 25°C