English
Language : 

LMX Datasheet, PDF (1/6 Pages) Illinois Capacitor, Inc. – Multiple Case Sizes - High Voltage – High Current
FEATURES Multiple Case Sizes - High Voltage – High Current
APPLICATIONS
Bulk Filtering – Switching Power Supplies
Operating Temperature Range
-40°C to +105°C (<100WVDC)
-25°C to +105°C (>160WVDC)
Capacitance Tolerance
+20% at 120 Hz, 20°C
Surge Voltage
Dissipation
Factor
tan δ
(120 Hz)
WVDC
SVDC
WVDC
Leakage Current
@20°C, Rated WVDC applied
10 16 25 35 50 63 80 100 160 200 250 350 400 450
13 20 32 44 63 79 100 120 200 250 300 400 450 500
10 16 25 35 50 63 80 100 160 200 250 350 400 450
.6 .45 .3 .25 .2 .15 .15 .15 .15 .15 .15 .15 .2 .2
For capacitances above 33000uF, add to DF value (Capacitance-33000) *0.1
10000
Time
5 Minutes
3√CV
Impedance Ratio
(120 Hz)
WVDC
-25°C/+20°C
-40°C/+20°C
10
6
15
16
6
15
25
6
15
35
6
15
50
4
15
63 80 100 160 200 250 350 400 450
33
388
8
8
8
8
15 15
-
-
-
-
-
-
5000 hours at 105°C with rated WVDC and ripple current applied
Load Life
Capacitance change
Dissipation factor
<20% of initial measured value
<200% of maximum specified value
Leakage current
<100% of maximum specified value
1000 hours at 105°C with no voltage applied
Shelf Life
Capacitance Change
Dissipation Factor
<20% of initial measured value
<200% of maximum specified value
Leakage Current
<100% of maximum specified value
Frequency (Hz)
Temperature (°C)
Ripple Current
Multipliers
WVDC
<100
160<V<250
60
0.9
0.8
120 400 1k
10k 50k 45
1.0 1.0 1.15 1.25 1.25 2.4
1.0 1.0 1.25 1.47 1.47 2.4
65
2.1
2.1
75
85 105
1.9 1.7
1
1.9 1.7
1
>350
0.8 1.0 1.0 1.3 1.47 1.47 2.4 2.1
1.9 1.7
1