FSB Datasheet, PDF (1/2 Pages) Illinois Capacitor, Inc. – High voltage – Low Leakage – low dissipation Factor
FEATURES
APPLICATIONS
High voltage – Low Leakage – low dissipation Factor
Emergency lights – Signal lights Mobile
Operating Temperature
Range
Capacitance Tolerance
Surge Voltage
WVDC
SVDC
Dissipation
Factor
Cap
tan δ
Leakage Current
@25°C, Rated WVDC
applied
Charge/ Discharge
Shelf Life
-20°C to +55°C
330
350
C<600 uF
.07
time
-10 to+20% at 120 Hz, 25°C
360
390
C>600 uF
.1
5 Minutes
1*C
5000 flashes at rated voltage applied at 5~35°C repeating
every 30 seconds thru a Xe flash tube having a discharge
resistance if 0.7~1.0Ω
Capacitance Change
Dissipation Factor
<10% of initial measured value
<150% of maximum specified value
Leakage Current
<150% of maximum specified value
500 hours at 70°C with no voltage applied
Capacitance Change <10% initial measured value
Dissipation Factor
<150% of maximum specified value
Leakage Current
<150% of maximum specified value
D
α
D1
L1
LL+/-2mm
S +/-1.0mm
W
22
0.5
D+ α
L+3
5.0
10
2.6
25
1.0
D+ α
L+3
5.5
10
3.0
30
1.0
D+ α
L+3
5.5
10
3.0
35
1.0
D+ α
L+3
5.5
10
3.0
40
1.0
D+ α
L+3
5.5
12.5
3.0
3757 W. Touhy Ave., Lincolnwood, Il 60712 ● (847)675-1760● Fax (847) 675-2850 ● www.illcap.com