English
Language : 

474BPA050M_16 Datasheet, PDF (1/2 Pages) Illinois Capacitor, Inc. – Bi-Polar/ non-polar 2000 hrs
FEATURES
Small size – Non/ Bi-Polar
APPLICATIONS
Audio Coupling – Crossover Networks
Operating Temperature
Range
Capacitance Tolerance
Surge
WVDC
Voltage
SVDC
Dissipation
WVDC
Factor
Tan δ
Leakage Current
Low Temperature
Stability
Impedance Ratio
(120 Hz)
WVDC
-25°C to 20°C
-40°C to +20°C
Load Life
Shelf Life
Ripple Current Multipliers
-40°C to +85°C
+20% at 120 Hz, 20°C
16 25 50 100
20 32 63 125
16 25 50 100
.22 .2 .14 .1
5 Minutes
.05CV or 3uA,
Whichever is greater
16 25 50 100
22 2
2
65 4
3
2000 hours at 85°C with rated WVDC and rated voltage reversed every 250 hours.
Capacitance Change
<20% of initial measured value
Dissipation Factor
<200% of maximum specified value
Leakage Current
<100% of maximum specified value
1000 hours at 85°C with no voltage applied
Capacitance Change
<20% of initial measured value
Dissipation Factor
<200% of maximum specified value
Leakage Current
<100% of maximum specified value
Capacitance
Frequency (Hz)
Temperature (°C)
μF
50 120 400 1k
10k 50k +85 +70 +60 +30
C<10
.72 1.0 1.25 1.45 1.65 1.7 1.0 1.3 1.5 1.8
10<C<100 .75 1.0 1.19 1.36 1.53 1.57 1.0 1.3 1.5 1.8
100<C<1000 .79 1.0 1.15 1.3 1.45 1.49 1.0 1.3 1.5 1.8
D5
6.3
8
10 12.5 16 18 22
25
d 0.5 0.5 0.6 0.6 0.6 0.8 0.8 0.8 0.8
B 0.5 0.5 0.5 0.5 0.8 0.5 0.5 1.0 1.0
L1=L+2.0mm Max.
mm
D1=D+0.5 Max.