English
Language : 

105TTA050M Datasheet, PDF (1/3 Pages) Illinois Capacitor, Inc. – Axial Lead - High Voltage
FEATURES
Axial Lead - High Voltage
APPLICATIONS
Filtering – Bypass – Coupling – Blocking
Operating Temperature
Range
Capacitance Tolerance
Surge
WVDC
voltage
SVDC
Dissipation
Factor
WVDC
Tan δ
Leakage current
Low
temperature
stability
Impedance ratio
(120 Hz)
WVDC
-25°C to
+20°C
-40°C to
+20°C
Load Life
Shelf Life
Ripple Current
Multipliers
-40°C to +85°C (10 to 350 WVDC)
-25°C to +85°C (450 WVDC)
+20% at 120 Hz, 20°C
10 16 25 35 50 63 100
160 200 250 350 450
13 20 32 44 63 79 125
200 250 300 400 500
10 16 25 35 50 63 100
160 200 250 350 450
.24 .20 .16 .14 .12 .1
.1
.2
.2
.2
.25 .25
Add .02 for every 1000uF above 1000uF
10 to 100 WVDC
160 to 450 WVDC
1 Minutes
2 Minutes
1 Minute
1 Minute
.03CV or 4uA,
Whichever is greater
.01CV or 3uA,
Whichever is greater
CV<1000
.04CV+100uA
CV>1000
.1CV+40uA
10 16 25 35 50 63 100 160 200 250 350 450
4
32
2
22
2
4
4
4
4
6
10 8 5
4
33
3
15
15
15
10
-
2000 hours at 85°C with rated WVDC and ripple current applied
Capacitance change <20% of initial measured value
Dissipation factor
<200% of maximum specified value
Leakage current
>100% of maximum specified value
1000 hours at 85°C with no voltage applied
Capacitance change <20% of initial measured value
Dissipation factor
<200% of maximum specified value
Leakage current
Capacitance
>100% of maximum specified value
Frequency (Hz)
Temperature (°C)
uF
50 120 400
1k
10k
50k
+85
+70 +60 +30
C<10
.8 1.0 1.3
1.45
1.65
1.7
1.0
1.3
1.5
1.8
10<C<100
.8 1.0 1.23
1.36
1.48 1.53
1.0
1.3
1.5
1.8
100<C<1000
.8 1.0 1.16
1.25
1.35 1.38
1.0
1.3
1.5
1.8
C>1000
.8 1.0 1.11
1.17
1.25 1.28
1.0
1.3
1.5
1.8
D 5 6.3
8
10 12.5 16 18 22
25
d 0.5 0.5 0.6 0.6 0.6 0.8 0.8 0.8 0.8
B 0.5 0.5 0.5 0.5 0.8 0.5 0.5 1.0 1.0
D< 10mm, L1=L+1.5mm Max.
mm
D> 10mm, L1=L+2mm Max.
D1=D+B Max.
Feb-17