English
Language : 

105DCN2R7S Datasheet, PDF (1/3 Pages) Illinois Capacitor, Inc. – Very fast charge/discharge High power density IEC 62391 compliant
FEATURES
Very fast charge/discharge – High power density – IEC 62391 compliant –
Circuit board mountable
APPLICATIONS
Battery backup/ alternative – Pulse power – Energy harvesting – LED Displays –
Mechanical actuators – Audio systems
Operating Temperature
Range
Storage Temperature
Capacitance Tolerance
@ 20°C
Surge voltage
WVDC
SVDC
Maximum Current
Operating Current
Leakage Current
Life time
(25°C)
Shelf Life
Life cycles
( 25°C) 1 cycle= Charge to WVDC
for 20s, constant voltage charging
for 10s, discharge to ½ WVDC for
20s, rest for 10 s
-40°C to +60°C
-40°C to +70°C
+30%/-10% (Q tolerance), +20%/-20% (M tolerance)
+10%/-10% (K tolerance), +50%/-20% (S tolerance)
2.7 5.4
2.8 5.7
See standard part listing
1 second discharge to ½ WVDC
5 second discharge to ½ WVDC
See standard part listing
72 hours,25°C
1000 hours with rated voltage applied at 60°C
Capacitance change <30% of initially measured values
ESR
<400% of initially specified values
Leakage current
< specified maximum value
500 hours with no voltage applied at 60°C
Capacitance change
ESR
Capacitance change
<30% of initially measured values
<400% of initially specified values
500,000 cycles
<30% of initially measured values
ESR change
<400% of initially specified values
D= 8 to 18mm
Lead spacing VS. Case diameter
D
8
10
16
18
S
3.5
5.0
7.5
7.5
d
0.6
0.6
0.8
0.8
L1=L+1.5mm
D1=D+05mm
S1=S+0.5mm