104MABA05KG Datasheet, PDF (1/6 Pages) Illinois Capacitor, Inc. – AC/Motor Run Film Capacitors | |||
|
MAB AC/Motor Run
Film Capacitors
®
15µF 5%ICE3N2E06VL0A2C5M2AAB400VAC C
⢠Motor Run
⢠SMPS
⢠General Purpose AC application
⢠High Frequency Electronic Ballasts
⢠Switching Capacitor for Industrial Controls ⢠Motor Speed Controls
Operating Temperature
Range
Capacitance Tolerance
Rated Voltage
Dissipation Factor
(max) at 20ËC.
Insulation Resistance
@20ËC(<70% RH)
for 1 minute at 100VDC
Dielectric Strength
Self Inductance
Capacitance Drift
Temperature Coefficient
Load Life Test
Capacitance Change â¤3%
Dielectric
Electrodes
Construction
Leads
Coating
-40ËC to +105ËC without use of approvals
-25ËC to +85ËC for use of approvals
+/- 10% at 1kHz, 20ËC
See Voltage Code Table
Voltage must be derated by 1.25% per °C exceeding 85°C.
Freq (kHz)
1
C⤠2.2µF
.06%
2.2µF<Câ¤15µF
.1%
15µF<Câ¤22µF
.12%
C>22µF
.14%
> 10,000M⦠x µF for C<1µF.
> 30,00M⦠x µF for Câ¥1µF.
160% of rated VAC for 60 seconds at 20ËC between leads.
200% of rated VAC for 60 seconds at 20ËC between leads
for EN 60252-1 approval.
3KV at 60HZ for 60 seconds between leads and case.
<1nH/mm of lead spacing and lead wire length.
<1.0% up to 40ËC after 2 years
-200ppm/ËC +/- 100ppm/ËC
125% of rated voltage at +85°C
200 hrs. for Class D (1000 hours expected life, continuous service)
600 hrs. for Class C (3000 hours expected life, continuous service)
2000 hrs. for Class B (10000 hours expected life, continuous service)
6000 hrs. for Class A (30000 hours expected life, continuous service)
Polypropylene
Vacuum Deposited Metal Layers
Metallized Film
Solid or Stranded Tinned Copper Wire
Solvent resistant plastic box (UL 94-V1) with epoxy fills (UL 94V-0)
®
182
3757 W. Touhy Ave., Lincolnwood, IL 60712 ⢠(847) 675-1760 ⢠Fax (847) 673-2850 ⢠www.illcap.com
|
▷ |