English
Language : 

104CKR050M_16 Datasheet, PDF (1/3 Pages) Illinois Capacitor, Inc. – Standard 2000 hour
FEATURES
Small size - High voltage - General purpose
APPLICATIONS
Bypass – Coupling – Filtering – De-coupling
Operating
Temperature Range
Capacitance
Tolerance
Surge
WVDC
Voltage
SVDC
Dissipation
Factor
WVDC
Tan δ
Leakage Current
Low
Temperature
Stability
Impedance
Ratio
(120 Hz)
WVDC
-25°C to +20°C
-40°C to +20°C
Load Life
Shelf Life
Ripple Current
Multipliers
-40°C to +85°C (6.3 to 100 WVDC)
-25°C to +85°C (160 to 500 WVDC)
+20% at 120 Hz, 20°C
6.3 10 16 25 35 50 63 100 160 200 250 350 400 450 500
7.9 13 20 32 44 63 79 125 200 250 300 400 450 500 550
6.3 10 16 25 35 50 63 100 160 200 250 350 400 450 500
.22 .19 .16 .14 .12 .1 .09 .08 .15 .15 .15
.2
.2
.2
.2
Add .02 for every 1000uF above 1000uF
6.3 to 100 WVDC
160 to 500 WVDC
2 Minutes
2 Minutes
.01CV or 3uA,
Whichever is greater
.03CV+10uA
6.3 10 16 25 35 50 63 100 160 200 250 350 400 450 500
5 432 2
2
2
2
3
3
4
6
7
7
8
10 8 6 5 3
3
3
3
-
-
-
-
-
-
-
2000 hours at 85°C with rated WVDC and ripple current applied
Capacitance Change <20% of initial measured value
Dissipation Factor
<200% of maximum specified value
Leakage Current
<100% of maximum specified value
1000 hours at 85°C with no voltage applied
Capacitance Change <20% initial measured value
Dissipation Factor
<200% of maximum specified value
Leakage Current
<100% of maximum specified value
WVDC
Capacitance
(uF)
50
Frequency (Hz)
120 300 1k 10k
Temperature (°C)
100k 85 70 65 60 45
6.3 to
100V
47
0.75 1.0 1.35 1.57 2
2.3 1.0 1.4 1.6 1.7 1.8
100 to 470 0.8 1.0 1.23 1.34 1.5 1.65 1.0 1.4 1.6 1.7 1.8
>560
0.85 1.0 1.1 1.13 1.15 1.4 1.0 1.4 1.6 1.7 1.8
350 to
450V
.47 to 4.7 0.65 1.0 1.35 1.75 2.3
6.8 to 82 0.75 1.0 1.25 1.5 1.75
100 to 1000 0.8 1.0 1.15 1.5 1.4
2.5 1.0 1.4 1.6 1.7 1.8
1.8 1.0 1.4 1.6 1.7 1.8
1.5 1.0 1.4 1.6 1.7 1.8
D
5 6.3 8
10 12.5 16 18
S 2.0 2.5 3.5 5.0 5.0 7.5 7.5
d 0.5 0.5 0.5 0.6 0.6 0.8 0.8
L1=L+1.5mm Max.
mm
D1=D+0.5mm Max.
S1=S+0.5 mm