Table 6. Electrical Parameters (continued)
Symbol
Parameter
Mode
Transmitter
– 7.0 V  VOD  VCC
IOSD Short circuit current
0 V  VOD  12 V
0 V  VOD  VCC
VhD
tPHL D,
tPLH D
tSKEW D
Hysteresis
Transmitter input to output
switching delay
Transmitter output skew
–
CL1 = CL2 = 100 pF
RDIFF = 54 
CL1 = CL2 = 100 pF
RDIFF = 54 
tPZH D,
tPZL D
tPHZ D,
tPLZ D
Transmitter enable time
from OFF to output high
(low)
Transmitter disable time
from output high (low) to
OFF
tRD, tFD
Rise or fall time of
differential output signal
tLD (SHDN),
tHD (SHDN)
Transmitter enable time
from shutdown to output
high (low)
CL = 100 pF
CL = 15 pF
RDIFF = 54 
CL1 = CL2 = 100 pF
CL = 15 pF
–
ST Data rate
Limit
Min Max
TA, C
Unit
–
240 25 ± 10 mA
250 –40; 85
240 25 ± 10
250 –40; 85
26 25 ± 10
25 –40; 85
–
200 2510 V
330
800 25 ± 10 ns
250 1000 –40; 85
–
90 25 ± 10 ns
100 –40; 85
–
2200 25 ± 10 ns
2500 –40; 85
–
90 25 ± 10 ns
100 –40; 85
220
620 25 ± 10 ns
200 750 –40; 85
–
4000 25 ± 10 ns
4500 –40; 85
600
– 25 ± 10 Kb/s
500
–40; 85
2012, February, ver. 01