IL7101N_16 Datasheet, PDF (1/8 Pages) IK Semicon Co., Ltd – Ground Fault Interrupter Earth Leakage Current Detector
TECHNICAL DATA
Ground Fault Interrupter Earth
Leakage Current Detector
IL7101
DESCRIPTION
The IL7101 is designed for use in earth leakage circuit
interrupters for operation directly off the AC Line in breakers.
It contains pre regulator, main regulator, after regulator, differential
amplifier, level comparator, latch circuit. The input in the differential
amp latch circuit. The input in the differential amplifier is connecting to
the secondary node of zero current transformer.
The level comparator generates high level when earth leakage
current is greater than some level.
FEATURE
• Low Power Consumption (PD=5mW) 100V/200V
• 100V/200V Common Built-in Voltage Regulator
• High Gain Differential Amplifier
• High Input Sensitivity
• Minimum External Parts
• Large Surge Margin
• Wide Operating Temperature Range (TА= -30 to 85°C)
• High Noise Immunity
• Meet U. L. 943 standards
ORDERING INFORMATION
IL7101N DIP
IL7101D SOP
ORDERING INFORMATION
Device
IL7101N
IL7101D
IL7101DT
Operating
Temperature Range
TA = -30 to 85 C
for all packages
Package
DIP-8
SOIC-8
SOIC-8
Shipping
Tube
Tube
Tape& Reel
ABSOLUTE MAXIMUM RATINGS
● Supply Voltage
● Supply Current
● Power Dissipation
● Operating Temperature
● Storage Temperature
20V
8mA
200mW
- 30 to 85°C
- 55 to 125°C
* Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device.
These are stress ratings only and functional operation of the device at these or any other conditions beyond those
indicated under “recommended operating conditions” is not implied.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.