IL54123_16 Datasheet, PDF (1/8 Pages) IK Semicon Co., Ltd – GROUND FAULT INTERRUPTER EARTH LEAKAGE CURRENT DETECTOR
IL54123
GROUND FAULT INTERRUPTER EARTH
LEAKAGE CURRENT DETECTOR
IL54123
Description
The IL54123N/D is designed for use in earth leakage circuit interrupters for
operation directly off the AC Line in breakers.
It contains pre regulator, main regulator, after regulator, differential amplifier,
level comparator, latch circuit. The input in the differential amp
latch circuit. The input in the differential amplifier is connect to the
secondary node of zero current transformer.
The level comparator generates high level when earth leakage current is
greater than some level.
Feature
• Low Power Consumption (PD=5mW) 100V/200V
• 100V/200V Common Built-in Voltage Regulator
• High Gain Differential Amplifier
• High Input Sensitivity (VT = 6.1mV Typ.)
• Minimum External Parts
• Large Surge Margin
• Wide Operating Temperature Range (TА= -30 to 80°C)
• High Noise Immunity
• Meet U. L. 943 standards
ORDERING INFORMATION
IL54123N DIP
IL54123D SOP
Absolute Maximum Ratings (T^=25°c)
 Supply Voltage
 Supply Current
 Power Dissipation
 Operating Temperature
 Storage Temperature
20V
8mA
200m W
- 30 to 80°C
- 55 to 125°C
* Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device.
These are stress ratings only and functional operation of the device at these or any other conditions beyond those
indicated under “recommended operating conditions” is not implied.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
January. 2011. rev.01