English
Language : 

ICS850S1601I Datasheet, PDF (9/12 Pages) Integrated Device Technology – 16:1 SINGLE-ENDED MULTIPLEXER
ICS850S1601I
16:1, SINGLE-ENDED MULTIPLEXER
Parameter Measurement Information, continued
CLKx
(static) CLKy
CLK_SELy
MUX Isolation
Spectrum
Q
MUX_ISOL
CLKx CLKy
20%
Q
80%
tR
Output Rise/Fall Time
80%
tF
20%
CLK0:
CLK15
Q
VDD
2
VDD
2
t
PD
Propagation Delay
Application Information
Recommendations for Unused Input Pins
Inputs:
CLK Inputs
For applications not requiring the use of a clock input, it can be left
floating. Though not required, but for additional protection, a 1kΩ
resistor can be tied from the CLK input to ground.
LVCMOS Control Pins
All control pins have internal pull-ups or pull-downs; additional
resistance is not required but can be added for additional
protection. A 1kΩ resistor can be used.
IDT™ / ICS™ 16:1, SINGLE-ENDED MULTIPLEXER
9
ICS850S1601BGI REV. A AUGUST 15, 2008