English
Language : 

9170B-01CS08LF Datasheet, PDF (8/12 Pages) Integrated Device Technology – CLOCK SYNCHRONIZER AND MULTIPLIER
IDT9170B
CLOCK SYNCHRONIZER AND MULTIPLIER
CLOCK SYNTHESIZER
AC Electrical Characteristics at 3.3 V
Unless stated otherwise, VDD = 3.3 V ±5%, Ambient Temperature 0 to +70° C
Parameter
Symbol
Conditions
Min. Typ. Max. Units
Input Frequency
Output Frequency, CLK1
Input Clock Rise Time
fI1
fI2
fO1
fO2
ICLKr
IDT9170B-01
IDT9170B-02
IDT9170B-01
IDT9170B-02
7
66.7 MHz
2
16.7 MHz
20
66.7 MHz
5
16.7 MHz
10
ns
Input Clock Fall Time
ICLKf
10
ns
Output Rise Time
Rise Time
tR1 0.8 to 2.0 V, 15 pF load
tR2 20% to 80% VDD, 15 pF
load
1.1
2
ns
1.8
4
ns
Output Fall Time
Fall Time
tF1 2.0 to 0.8 V, 15 pF load
tF2 80% to 20% VDD, 15 pF
load
0.8
2
ns
1.2
3
ns
Output Duty Cycle,
IDT9170B-01
dT1 15 pF load, Note 2, 3
40
52
60
%
Output Duty Cycle,
IDT9170B-02
dT2 15 pF load, Note 2, 3
45
51
55
%
One Sigma Jitter
150 300 ps
Absolute Jitter
tabs1
CLK1>10 MHz (-01)
CLK1>2.5 MHz (-02)
-500
500 ps
tabs2 CLK1<10 MHz (-01)
-2
CLK1<2.5 MHz (-02)
2
%
FBIN to IN Skew
Tskew1 15 pF load 3.0<VDD<
3.7, Note 2, 4
-4.0 -1.0 1.5 ns
Tskew2 15 pF load 3.0<VDD<
3.7, Note 2, 4
-3.0 -1.0 1.5 ns
CLK1 to CLK2 Skew
Tskew3 Note 2, 4, 15 pF load
-2.0 -0.9 0
ns
Parameters guaranteed by design and characterization. Not 100% tested in production.
Note 1: It may be possible to operate the IDT9170B outside of these ranges. Consult IDT for your specific
application.
Note 2: All AC specifications are measured with a 50Ω transmission line, load teminated with 50Ω to 1.4 V.
Note 3: Duty cycle measured at 1.4 V.
Note 4: Skew measured at 1.4 V on rising edges. Positive sign indicates the first signal precedes the second signal.
IDT™ CLOCK SYNCHRONIZER AND MULTIPLIER
8
IDT9170B
REV B 052609