English
Language : 

9DBU0841 Datasheet, PDF (6/17 Pages) Integrated Circuit Systems – slew rate for each output
9DBU0841 DATASHEET
Electrical Characteristics–Input/Supply/Common Parameters–Normal Operating
Conditions
TA = TAMB, Supply Voltages per normal operation conditions, See Test Loads for Loading Conditions
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX UNITS NOTES
Supply Voltage
VDDx
Supply voltage for core and analog
1.425
1.5
1.575
V
Output Supply Voltage
VDDIO
Supply voltage for Low Power HCSL Outputs
0.95 1.05-1.5 1.575
V
Ambient Operating
Temperature
TAMB
Commmercial range
Industrial range
0
25
70
°C
1
-40
25
85
°C
1
Input High Voltage
Input Mid Voltage
Input Low Voltage
Input Current
Input Frequency
Pin Inductance
Capacitance
Clk Stabilization
VIH
Single-ended inputs, except SMBus
0.75 VDD
VDD + 0.3 V
VIM
Single-ended tri-level inputs ('_tri' suffix)
0.4 VDD
0.6 VDD
V
VIL
Single-ended inputs, except SMBus
-0.3
0.25 VDD V
IIN
Single-ended inputs, VIN = GND, VIN = VDD
-5
Single-ended inputs
5
uA
IINP
VIN = 0 V; Inputs with internal pull-up resistors
-200
VIN = VDD; Inputs with internal pull-down resistors
200
uA
Fibyp
Bypass mode
1
167
MHz
2
Fipll
100MHz PLL mode
20
100.00 110
MHz
2
Lpin
7
nH
1
CIN
Logic Inputs, except DIF_IN
1.5
5
pF
1
CINDIF_IN
DIF_IN differential clock inputs
1.5
2.7
pF
1,5
COUT
Output pin capacitance
6
pF
1
TSTAB
From VDD Power-Up and after input clock
stabilization or de-assertion of PD# to 1st clock
1
ms
1,2
Input SS Modulation
Frequency PCIe
fMODINPCIe
Allowable Frequency for PCIe Applications
(Triangular Modulation)
30
33
kHz
Input SS Modulation
Frequency non-PCIe
fMODIN
Allowable Frequency for non-PCIe Applications
(Triangular Modulation)
0
66
kHz
OE# Latency
tLATOE#
DIF start after OE# assertion
DIF stop after OE# deassertion
1
3
clocks 1,3
Tdrive_PD#
tDRVPD
DIF output enable after
PD# de-assertion
300
us
1,3
Tfall
Trise
SMBus Input Low Voltage
SMBus Input High Voltage
SMBus Output Low Voltage
SMBus Sink Current
Nominal Bus Voltage
SCLK/SDATA Rise Time
SCLK/SDATA Fall Time
SMBus Operating
Frequency
tF
tR
VILSMB
VIHSMB
VOLSMB
IPULLUP
VDDSMB
tRSMB
tFSMB
fMAXSMB
Fall time of single-ended control inputs
Rise time of single-ended control inputs
VDDSMB = 3.3V, see note 4 for VDDSMB < 3.3V
@ IPULLUP
@ VOL
Bus Voltage
(Max VIL - 0.15) to (Min VIH + 0.15)
(Min VIH + 0.15) to (Max VIL - 0.15)
Maximum SMBus operating frequency
2.1
4
1.425
5
ns
2
5
ns
2
0.6
V
3.3
V
4
0.4
V
mA
3.3
V
1000
ns
1
300
ns
1
400
kHz
6
1Guaranteed by design and characterization, not 100% tested in production.
2Control input must be monotonic from 20% to 80% of input swing.
3Time from deassertion until outputs are >200 mV
4 For VDDSMB < 3.3V, VIHSMB >= 0.8xVDDSMB
5DIF_IN input
6The differential input clock must be running for the SMBus to be active
8 O/P 1.5V PCIE GEN1-2-3 ZDB/FOB W/ZO=100OHMS
6
REVISION C 04/22/15