IDT
AC Measurement Conditions
Symbol Parameter
CL Load capacitance
Input rise and fall times
Input levels
Input and output timing reference levels
AC Measurement I/O Waveform
Min.
Max.
100
50
0.2*VDD to 0.8*VDD
0.3*VDDto 0.7*VDD
Units
pF
ns
V
V
Input Parameters for the TS3001GB2A0
Symbol Parameter1,2
CIN Input capacitance (SDA)
CIN Input rise and fall times
ZEIL Ei (SA0,SA1) input impedance
ZEIH Ei (SA0,SA1) input impedance
tSP Pulse width ignored (input filter on
SCL and SDA)
Test Condition
VIN< 0.3* VDD
VIN> 0.7* VDD
Single glitch, f < 100 KHz
Single glitch, f> 100 KHz
1.TA=25°C, f=400 kHz
2.Verified by design and characterization not necessarily tested on all devices
Min.
30
800
Max.
8
6
100
50
Units
pF
ns
k
k
ns
4 of 23