Recommended Operation Conditions
Parameter
Ambient Operating Temperature (ICS345RP)
Ambient Operating Temperature (ICS345RIP)
Power Supply Voltage (measured in respect to GND)
Power Supply Ramp Time
Min.
0
-40
+3.15
Typ.
+3.3
Max.
+70
+85
+3.45
4
Units
°C
°C
V
ms
DC Electrical Characteristics
Unless stated otherwise, VDD = 3.3V ±5%, Ambient Temperature -40 to +85°C
Parameter
Symbol
Conditions
Min.
Operating Voltage
VDD
3.15
Configuration Dependent -
See VersaClockTM
Estimates
Operating Supply Current IDD Nine 33.3333 MHz outs,
Input High Voltage
PDTS = 1, no load, Note 1
PDTS = 0, no load, Note 1
Input High Voltage
VIH S2:S0
2
Input Low Voltage
VIL S2:S0
Input High Voltage, PDTS VIH
VDD-0.5
Input Low Voltage, PDTS VIL
Input High Voltage
VIH ICLK
VDD/2+1
Input Low Voltage
VIL ICLK
Output High Voltage
(CMOS High)
VOH IOH = -4 mA
VDD-0.4
Output High Voltage
VOH IOH = -12 mA
2.4
Output Low Voltage
VOL IOL = 12 mA
Short Circuit Current
IOS
Nominal Output
ZO
Impedance
Internal pull-up resistor
Internal pull-down
resistor
RPUS
RPD
S2:S0, PDTS
CLK outputs
Input Capacitance
CIN Inputs
Typ.
23
20
±70
20
250
525
4
Max.
3.45
Units
V
mA
mA
µA
V
0.4
V
V
0.4
V
V
VDD/2-1 V
V
V
0.4
V
mA
Ω
kΩ
kΩ
pF
Note 1: Example with 25 MHz crystal input with nine outputs of 33.3 MHz, no load, and VDD = 3.3 V.
MDS 345 D
5
Revision 090704
Integrated Circuit Systems, Inc. ● 525 Race Street, San Jose, CA 95126 ● tel (408) 297-1201 ● www.icst.com