Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS501A. These ratings,
which are standard values for ICS commercially rated parts, are stress ratings only. Functional operation of
the device at these or any other conditions above those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods can
affect product reliability. Electrical parameters are guaranteed only over the recommended operating
temperature range.
Item
Supply Voltage, VDD
All Inputs and Outputs
Ambient Operating Temperature
Storage Temperature
Soldering Temperature
Rating
7V
-0.5V to VDD+0.5V
-40 to +85°C
-65 to +150°C
260°C
Recommended Operation Conditions
Parameter
Ambient Operating Temperature
Power Supply Voltage (measured in respect to GND)
Min.
0
+3.0
Typ.
Max.
+70
+3.6
Units
°C
V
DC Electrical Characteristics
VDD=3.3 V ±10% , Ambient temperature 0 to +70°C, unless stated otherwise
Parameter
Symbol Conditions
Min. Typ.
Max. Units
Operating Voltage
VDD
3.0
3.6
V
Input High Voltage, ICLK only
Input Low Voltage, ICLK only
Input High Voltage
Input Low Voltage
Input High Voltage
Input Low Voltage
Output High Voltage
Output Low Voltage
IDD Operating Supply Current, 20
VIH ICLK (pin 1)
(VDD/2)+1
V
VIL ICLK (pin 1)
(VDD/2)-1 V
VIH OE (pin 7)
2.0
V
VIL OE (pin 7)
0.8
V
VIH S0, S1
VDD-0.5
V
VIL S0, S1
0.5
V
VOH IOH = -12 mA
2.4
V
VOL IOL = 12 mA
0.4
V
No load, 100M
20
mA
Short Circuit Current
CLK output
+70
mA
MDS 501A B
4
Revision 120704
Integrated Circuit Systems ● 525 Race Street, San Jose, CA 95126 ● tel (408) 297-1201 ● www.icst.com