English
Language : 

IS61SP12836 Datasheet, PDF (12/14 Pages) Integrated Circuit Solution Inc – 128K x 36 SYNCHRONOUS PIPELINED STATIC RAM
IS61SP12836
SNOOZE AND RECOVERY CYCLE SWITCHING CHARACTERISTICS (Over Operating Range)
Symbol Parameter
-166
-150
-133
-117
-5
Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Unit
tKC Cycle Time
6 — 6.7 — 7.5 — 8.5 — 10 — ns
tKH Clock High Time
2.4 — 2.6 — 2.8 — 3.4 —
4 — ns
tKL
Clock Low Time
2.4 — 2.6 — 2.8 — 3.4 —
4 — ns
tKQ Clock Access Time
— 3.5 — 3.8 — 4
—4
—5
ns
tKQX(1) Clock High to Output Invalid
1.5 — 1.5 — 1.5 —
2 — 2.5 — ns
tKQLZ(1,2) Clock High to Output Low-Z
0—
0—
0—
0—
0 — ns
tKQHZ(1,2) Clock High to Output High-Z
1.5 3.6 1.5 6.7 1.5 7.5 1.5 8.5 1.5 10
ns
tOEQ Output Enable to Output Valid — 3.5 — 3.5 — 3.9 — 4
—5
ns
tOEQX(1) Output Disable to Output Invalid 0 —
0—
0—
0—
0 — ns
tOELZ(1,2) Output Enable to Output Low-Z 0 —
0—
0—
0—
0 — ns
tOEHZ(1,2) Output Disable to Output High-Z 2 3.5
2 3.5
2 3.8
24
25
ns
tAS Address Setup Time
1.5 — 1.5 — 1.5 — 1.5 — 1.5 — ns
tSS Address Status Setup Time
1.5 — 1.5 — 1.5 — 1.5 — 1.5 — ns
tCES Chip Enable Setup Time
1.5 — 1.5 — 1.5 — 1.5 — 1.5 — ns
tAH Address Hold Time
0.5 — 0.5 — 0.5 — 0.5 — 0.5 — ns
tSH Address Status Hold Time
0.5 — 0.5 — 0.5 — 0.5 — 0.5 — ns
tCEH Chip Enable Hold Time
0.5 — 0.5 — 0.5 — 0.5 — 0.5 — ns
tZZS ZZ Standby
2—
2—
2—
2—
2 — cyc
tZZREC ZZ Recovery
2—
2—
2—
Notes:
1. Guaranteed but not 100% tested. This parameter is periodically sampled.
2. Tested with load in Figure 2.
2—
2 — cyc
12
Integrated Circuit Solution Inc.
SSR012-0B