English
Language : 

X24C04 Datasheet, PDF (9/18 Pages) Xicor Inc. – Serial E2PROM
X24C04
ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias .................. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to V SS ............................ –1.0V to +7.0V
D.C. Output Current ............................................ 5 mA
Lead Temperature (Soldering,
10 Seconds)
............................. 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of the
device at these or any other conditions above those
indicated in the operational sections of this specification is not
implied. Exposure to absolute maximum rating condition
for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Supply Voltage
Limits
Commercial
0°C
70°C
X24C04
4.5V to 5.5V
Industrial
–40°C
+85°C
X24C04-3.5
3.5V to 5.5V
Military
–55°C
+125°C
X24C04-3
3V to 5.5V
3836 PGM T02
X24C04-2.7
2.7V to 5.5V
3836 PGM T03
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified)
Symbol
Parameter
Limits
Min.
Max. Units
Test Conditions
ICC1
VCC Supply Current (Read)
1
ICC2
VCC Supply Current (Write)
3
I (1)
SB1
VCC Standby Current
150
I (1)
SB2
VCC Standby Current
50
ILI
ILO
VlL(2)
V IH(2)
VOL
Input Leakage Current
Output Leakage Current
Input Low Voltage
Input High Voltage
Output Low Voltage
10
10
–1.0 VCC x 0.3
VCC x 0.7VCC + 0.5
0.4
CAPACITANCE TA = 25°C, f = 1.0MHz, VCC = 5V
Symbol
Parameter
SCL = VCC x 0.1/VCC x 0.9 Levels
mA @ 100 KHz, SDA = Open, All Other
Inputs = GND or VCC – 0.3V
∝A SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC, VCC = 5.5V
∝A SCL = SDA = VCC – 0.3V, All Other
Inputs = GND or VCC,
VCC = 3V
∝A VIN = GND to VCC
∝A VOUT = GND to VCC
V
V
V IOL = 3 mA
3839 PGM T03
Max. Units
Test Conditions
C (3)
I/O
CIN(3)
Input/Output Capacitance (SDA)
Input Capacitance (A0, A1, A2, SCL)
Notes:(1)Must perform a stop command prior to measurement.
(2)VIL min. and VIH max. are for reference only and are not tested.
(3)This parameter is periodically sampled and not 100% tested.
8
pF
6
pF
VI/O = 0V
VIN = 0V
3839 PGM T05
9