English
Language : 

X25057 Datasheet, PDF (8/16 Pages) Xicor Inc. – 5MHz Low Power SPI Serial E 2 PROM with IDLock™ Memory
X25057
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias ................... –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to VSS ................................... –1V to +7V
D.C. Output Current.............................................. 5mA
Lead Temperature
(Soldering, 10 seconds) .............................. 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification
is not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
–40°C
Max.
+70°C
+85°C
7033 FRM T04
Supply Voltage
X25057
X25057-2.7
X25057-1.8
Limits
4.5V to 5.5V
2.7V to 5.5V
1.8V to 3.6V
7033 FRM T05
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions, unless otherwise specified.)
Symbol
Parameter
ICC1
VCC Supply Current (Write)
ICC2
VCC Supply Current (Read )
ISB
ILI
ILO
VIL(1)
VIH(1)
VOL1
VOL2
VOL3
VOH1
VOH2
VOH3
VCC Supply Current
(Standby)
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Output LOW Voltage
Output LOW Voltage
Output HIGH Voltage
Output HIGH Voltage
Output HIGH Voltage
POWER-UP TIMING
Limits
Min.
Max.
3
400
1
Units
Test Conditions
mA SCK = VCC x 0.1/VCC x 0.9 @ 5MHz, SO =
Open, CS = VSS
∝A SCK = VCC x 0.1/VCC x 0.9 @ 5MHz, SO =
Open, CS = VSS
∝A CS = VCC, VIN = VSS or VCC
–0.5
VCC x 0.7
VCC – 0.8
VCC – 0.4
VCC – 0.2
10
10
VCC x 0.3
VCC + 0.5
0.4
0.4
0.4
∝A VIN = VSS to VCC
∝A VOUT = VSS to VCC
V
V
V VCC > 3.3V, IOL = 2.1mA
V 2V < VCC = 3.3V, I OL = 1mA
V VCC = 2V, I OL = 0.5mA
V VCC > 3.3V, IOH = -1.0mA
V 2V < VCC = 3.3V, I OH = -0.4mA
V VCC = 2V, I OH = -0.25mA
7033 FRM T06
Symbol
tPUR(2)
tPUW(2)
Parameter
Power-up to Read Operation
Power-up to Write Operation
Min.
Max.
1
5
Notes: (1)VIL Min. and VIH Max. are for reference only and are not 100% tested.
(2)tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These parameters
are periodically sampled and not 100% tested.
Units
ms
ms
7033 FRM T07
8