English
Language : 

X76F640 Datasheet, PDF (11/17 Pages) Xicor Inc. – Secure SerialFlash
X76F640
AC CHARACTERISTICS
AC Specifications (Over the recommended operating conditions)
Symbol
Parameter
fSCL
SCL Clock Frequency
tIN (1)
tAA
Pulse width of spikes which must be suppressed by the
input filter
SCL LOW to SDA Data Out Valid
tBUF
tLOW
tHIGH
tSU:STA
tHD:STA
tSU:DAT
tHD:DAT
tSU:STO
tDH
Time the bus must be free before a new transmit can
start
Clock LOW Time
Clock HIGH Time
Start Condition Setup Time
Start Condition Hold Time
Data In Setup Time
Data In Hold Time
Stop Condition Setup Time
Data Output Hold Time
tR
SDA and SCL Rise Time
tF
SDA and SCL Fall Time
tSU:CS
tHD:CS
fSCL_RST
CS Setup Time
CS Hold Time
SCL Clock Frequency during Response to Reset
tSR
tNOL
tRST
tSU:RST
Device Select to RST active
RST to SCL Non-Overlap
RST High Time
Response to Reset Setup Time
tLOW_RST Clock LOW during Response to Reset
tHIGH_RST
tRDV
tCDV
Clock HIGH during Response to Reset
RST LOW to SDA Valid During Response to Reset
CLK LOW to SDA Valid During Response to Reset
tDHZ
Device Deselect to SDA high impedance
Notes:1.
Notes:2.
Typical values are for TA = 25˚C and VCC = 5.0V
Cb = Total Capacitance of one bus line in pf.
Min
0
50
0.1
1.3
1.3
0.6
0.6
0.6
100
0
0.6
50
20 + 0.1 x Cb(2)
20 + 0.1 x Cb(2)
200
100
200
500
2.25
1.25
1.25
1.25
0
0
0
Typ(1)
100
0.3
Max
400
0.9
300
300
300
400
500
500
500
Units
KHz
ns
∝s
∝s
∝s
∝s
∝s
∝s
ns
∝s
∝s
ns
ns
ns
ns
ns
kHz
ns
ns
∝s
∝s
∝s
∝s
ns
ns
ns
7025 FM T14
11