English
Language : 

IC-JE_15 Datasheet, PDF (7/11 Pages) IC-Haus GmbH – PWM RELAY/SOLENOID DRIVER
iC-JE
PWM RELAY/SOLENOID DRIVER
APPLICATIONS INFORMATION
Rev G3, Page 7/11
Setting the coil current
The following equations can be given for the energise
and hold modes of the PWM control using Electrical
Characteristics Nos. 403 to 405:
K2
RSET =
(4)
I(OUT )hold
Example
For a relay with a energising current of 100 mA (66 mA
hold current) RSET is calculated as:
K1
RSET =
(3)
I(OUT )start
RSET = 3250 ΩA = 32.5 kΩ
(5)
0.1 A
Application circuits
10...45 V
10...45 V
LOUT
0.01...10 H
LOUT
0.01...10 H
IN LED VB
OUT
IN
iC−JE
100 nF
CONTROL
ISET
RSET
10...60 kΩ
GND
GND
Figure 2: Driver/relay combination activated via the
external control input IN
LED VB
IN
OUT
100 nF
iC−JE
CONTROL
ISET
GND
RSET
10...60 k Ω
GND
Figure 3: Driver/relay combination activated via the
supply pin GND
10...45 V
10...45 V
LOUT
0.01...10 H
LED VB
IN
OUT
0...100 nF
iC−JE
CONTROL
ISET
RSET
10...60 kΩ
GND
GND
Figure 4: Driver/relay combination activated via the
supply pin VB
LOUT
0.01...10 H
100 nF
R1
C1
LED VB
IN
OUT
iC−JE
ISET
R2
CONTROL
GND
Figure 5: Increased energizing current due to the par-
allel RC-circuit