English
Language : 

IC-RC1000 Datasheet, PDF (5/10 Pages) IC-Haus GmbH – SIN/COS SIGNAL SAFETY MONITOR IC
iC-RC1000
preliminary
SIN/COS SIGNAL SAFETY MONITOR IC
Rev A2, Page 5/10
ABSOLUTE MAXIMUM RATINGS
These ratings do not imply permissible operating conditions; functional operation is not guaranteed.
Exceeding these ratings may damage the device.
Item Symbol Parameter
No.
Conditions
G001 V(VCC) Voltage at VCC1, VCC2
G002 I(VCC) Current in VCC1, VCC2
G003 Vin()
Voltage at PSIN, NSIN, PCOS, NCOS
G004 Iin()
Current in PSIN, NSIN, PCOS, NCOS
G005 Vout()
Voltage at ERR, OK
G006 Iout()
Current in ERR, OK
G007 Ilu()
G008 Vd()
Pulse Current in all pins
(latch-up susceptibility)
ESD Susceptibility at all pins
according to Jedec Standard No. 78;
Ta = 25 °C, pulse duration to 10 ms,
VCC1 = VCC1max, VCC2 = VCC2max,
Vlu() = (-0.5...+1.5) x Vpin()max
HBM 100pF discharged through 1.5 kΩ
Min.
-0.3
-10
-0.3
-10
-0.3
-10
-100
Unit
Max.
7
V
25
mA
7
V
10
mA
7
V
25
mA
100
mA
2
kV
THERMAL DATA
Operating conditions: VCC1 = 5 V ±10 %, VCC2 = 5 V ±10 %
Item Symbol Parameter
No.
Conditions
T01 Ta
Operating Ambient Temperature Range
(extended range on request)
T02 Rthja
Thermal Resistance Chip to Ambient
Unit
Min. Typ. Max.
-40
110 °C
30
K/W
All voltages are referenced to ground unless otherwise stated.
All currents flowing into the device pins are positive; all currents flowing out of the device pins are negative.