English
Language : 

IC-GE Datasheet, PDF (4/11 Pages) IC-Haus GmbH – PWM RELAY/SOLENOID DRIVER
iC-GE
PWM RELAY/SOLENOID DRIVER
preliminary
Rev A0.6, Page 4/11
ELECTRICAL CHARACTERISTICS
Operating Conditions: VB = 10...36 V, LSW = 0.01...10 H, RACT = 5...50 kΩ, RHOLD = 5...50 kΩ, Tj = -40...125 °C.
Item Symbol Parameter
No.
Conditions
Unit
Min. Typ. Max.
Total Device
001 VB
Permissible Supply Voltage
Range
10
36
V
002 I(VB)
Supply Current in VB
EN < 0.8 V
20
µA
003 I(VB)
Supply Current in VB
EN = hi
0.5
4
mA
004 Vc()lo
Clamp Voltage lo at all Pins ex- I() = -4 mA, other Pins open
cept SYNC
-1.4
-0.3
V
005 Vc()lo
Clamp Voltage lo an SYNC
I() = -4 mA, andere Pins offen
-7
V
006 Vc()hi
Clamp Voltage hi at VB, EN,
I() = 4 mA, other Pins open
37
V
DIAG, SYNC
007 Vc()hi
Clamp-Voltage hi at IACT, IHOLD, I() = 4 mA, other pins open
TACT
7
V
008 Vc()hi
5
V
009 Vc()hi
Clamp-Spannung hi an SW
I(OUT) = 4 mA, other Pins open
10
17
V
Driver Output SW
101 Vs()lo
Saturation Voltage lo
I(SW) = 1000 mA (see Figure 1)
600 mV
102 Vs()lo
Saturation Voltage lo
I(SW) = 100 mA (see Figure 1)
100 mV
103 I(SW)
PWM-Current Range
100
1000 mA
104 Isc()
Short-circuit Current
V(SW) = VB
1.1
4
A
105 Vc()hi
Clamp Voltage hi at PWM-Free- Vc()hi = V(SW) − VB;
Wheeling
EN = hi, I(SW) = 1000 mA (see Figure 1)
600 mV
106 Vc()hi
Clamp Voltage hi at PWM-Free- Vc()hi = V(SW) − VB;
Wheeling
EN = hi, I(SW) = 100 mA (see Figure 1)
100 mV
107 Vc()off Clamp Voltage hi at Turn-off
Vc()hi = V(SW) − VB;
12
15
17
V
EN: hi → lo, I(SW) = 1000 mA (see Figure 1)
108 IIK()
Leakage Current
EN = lo, V(SW) = 0...VB
1
10
µA
109 twon()min Minimum PWM Turn-on Duration EN = hi, I(SW) > I(SW)act resp. I(SW)hold
250
(see Figure 1)
1000 ns
Input EN
201 Vt()on
Threshold Voltage hi
1.1
1.4
V
202 Vt()off
Threshold Voltage lo
0.8
1.1
V
203 Vt()hys Hysteresis
Vt()hys = Vt()on − Vt()off
200
400 mV
204 Ipd()
Pull-down Current
V(EN) = 0.8...36 V
20
µA
205 tp(VB-SW) Turn-on Delay after power-up EN = VB, VB = VBoff → VBon
40
µs
206 tp(EN-SW) Turn-on Delay
EN: lo → hi until SW active
30
µs
207 tp(EN-SW) Turn-off Delay
EN: hi → lo until SW inactive
10
µs
208 tp(EN-
DIAG)
Delay Time from EN to DIAG = hi no error
or LED permanently on
20
µs
Status Monitor DIAG
401 Ipd()
Pull-down Current
V(DIAG) = 6 V...VB, SW active, no error
3
5
8
mA
402 VBlo
Permissible Supply Voltage for
LED operation at DIAG
6
36
V
403 V()hi
Hi-Level at DIAG
without LED
4.5
6.5
V
404 f()
Frequency on Error
1.8 2.4 3.6
Hz
405 Vs()lo
Saturation Voltage lo
I(DIAG) = 200 µA, without LED
0.4
V
406 Ipu()
Pull-up Current
V(DIAG) = 0 ...4 V
-120 -100 -80
µA
407 VBon
Turn-on Threshold at VB
V(DIAG): lo → hi
8
8.5
9
V
408 VBoff
Undervoltage Threshold at VB Decreasing voltage VB, V(DIAG): hi → lo
7.5
8
8.5
V
409 VBhys
Hysteresis
VBhys = VBon − VBoff
200 500 800 mV
410 Toff
Thermal Shutdown Temperature
140
170
°C
411 Ton
Thermal Release Temperature Decreasing temperature
120
150
°C
412 Thys
Thermal Shutdown Hysteresis Thys = Toff − Ton
10
20
30
°C