English
Language : 

IC-MHA_14 Datasheet, PDF (2/10 Pages) IC-Haus GmbH – ANALOG ANGULAR HALL SENSOR
iC-MHA
ANALOG ANGULAR HALL SENSOR
preliminary
Rev B2, Page 2/10
DESCRIPTION
The iC-MHA is a position sensor with integrated Hall
sensors for scanning a permanent magnet. The sig-
nal conditioning unit generates constant-amplitude
sine and cosine voltages that can be used for angle
calculation.
Sine and cosine signals are availabe via line driver
outputs (100 Ω load)
PACKAGING INFORMATION QFN28 5 x5 mm² to JEDEC MO-220-VHHD-1
PIN CONFIGURATION QFN28 5 x 5mm²
PSOUT NSOUT
nc nc
nc nc PT22
28 27 26 25 24 23 22
PT1 1
NERR 2
VPA 3
VNA1 4
PT5 5
PT6 6
PT7 7
MHA
21 PT21
20 PT20
19 VPD
18 VND
17 PT17
16 PT16
15 PT15
8 9 10 11 12 13 14
C221110
nc nc
PT12
nc
PCOUT NCOUT VNA2
PIN FUNCTIONS
No. Name
Function
2 NERR
Error Output (active low)
3 VPA
+5 V Analog Supply Voltage
4,13 VNA1, VNA2 Analog Ground
10 PCOUT
Positive Cosine Output
11 NCOUT
Negative Cosine Output
18 VND
Digital Ground
19 VPD
+5 V Digital Supply Voltage
25 NSOUT
Negative Sine Output
26 PSOUT
Positive Sine Output
TP
Thermal-Pad
8,9 nc
14 nc
23,24 nc
27,28 nc
not connected
not connected
not connected
not connected
1 PT1
5 PT5
6 PT6
7 PT7
12 PT12
15 PT15
16 PT16
17 PT17
20 PT20
21 PT21
22 PT22
Pins for device test and
factory calibration:
connect to VND
connect to VND
connect to VPD
do not connect (leave open)
connect to VND
do not connect (leave open)
do not connect (leave open)
do not connect (leave open)
do not connect (leave open)
do not connect (leave open)
do not connect (leave open)
The Thermal Pad is to be connected to VNA1, VNA2 and heat sink area.