LFU10 Datasheet, PDF (1/2 Pages) ice Components, Ins. – Line Filters
ICE Components, Inc.
Line Filters
Voice: 800.729.2099
Fax: 678.560.9304
cust.serv@icecomp.com
www.icecomponents.com
LFU10 Series
Features
• Broad frequency attenuation
• UU cores for compact Design
• Wide selection available
• Custom designs available
Applications
• Off-Line Switch Mode Power
Supplies
• Conducted EMI Filters
• Office Equipment
• Medical Equipment
Packaging: Tray=100 pieces, Box=12 trays, Box=1200 pieces
LFU10 Vertical
18.5 max
17.0 max
LFU10 Horizontal
18.5 max
18.0 max
21.5
BBB- CCC -DE
16.5
max
max
color dot
for pin 1
13.0
4.0+/-0.5
Front View
2
3
0.7 dia
1
10. 0
Side View
color dot
for pin 1
13.0
4.0+/-0.5
Front View
2
3
4
6.0 max
1
10.0
Side View
0.7 dia
3.8 max
4
BBB CCC DE
2
3
2
3
1
4
Top View
Electrical Specifications
Part Number
LFU10-055-153-2_
LFU10-080-782-2_
LFU10-100-382-2_
LFU10-130-202-2_
LFU10-170-781-2_
LFU10-220-711-2_
LFU10-060-902-4_
LFU10-090-312-4_
LFU10-130-182-4_
LFU10-180-112-4_
LFU10-230-501-4_
LFU10-300-281-4_
Inductance1
(mH nom.)
21.68
11.11
5.42
2.87
1.12
1.01
12.94
4.49
2.51
1.61
0.71
0.40
Schematic
Inductance1
(mH min.)
15.18
7.78
3.79
2.01
0.78
0.71
9.06
3.14
1.76
1.13
0.50
0.28
DCR
(Ω max.)
1.100
0.550
0.300
0.150
0.075
0.060
0.850
0.350
0.190
0.120
0.060
0.040
1
4
Top View
Rated5
Current (A)
0.55
0.8
1.0
1.3
1.7
2.2
0.6
0.9
1.3
1.8
2.3
3.0
SRF
(kHz, typ.)
254
426
617
803
1614
2025
626
1219
1636
2191
4315
4440
Schematic
units: mm
1. Tested at 1 kHz,
0.1 Vrms, series.
2. Electrical specs at 25˚ C.
3. Operating range: -40˚ C
to +130˚ C.
4. Meets UL 94V-0.
5. Rated current produces
a temperature rise of
40˚ C.
6. Specify H or V at end
of part number for
Horizontal or Vertical
core arrangement.
Specifications subject to change without notice.
(10/06) LFU10-1