English
Language : 

I04-4R7-3R3 Datasheet, PDF (1/2 Pages) ice Components, Ins. – Output Power Chokes
ICE Components, Inc.
Output Power Chokes
Voice: 800.729.2099
Fax: 678.560.9304
cust.serv@icecomp.com
www.icecomponents.com
I04 Series
Applications
• 2nd Stage Output Filter for Offline Power Supplies
Features
• Designed for Use with Popular Flyback Controllers
• Cost Effective Toroid Design
• Low DCR to Minimize Losses
• Range of Inductance Values at Each Current Rating
The I04 series has been designed in collaboration with On Semiconductor to work with the NCP1207 controller as a second
stage output filter. With multiple inductance values at popular output current levels, the I04 series provides solutions for
a range of output filtering needs. The low DCR values minimize the voltage drop across the inductor and minimize losses
due to temperature rise. The low cost designs utilize powdered iron cores from Micrometals to eliminate the risk of long
term instability.
The NCP1207 is a PWM current-mode controller for free running quasi-resonant operation. Applications include notebook
and offline battery chargers, consumer electronics, set-top boxes, medical power supplies, etc…
Electrical Specifications
Part Number
Loaded Inductance (µH)1
DCR
Temp Rise5
0A
3.3A
6A
8A 10A 13A 16A (mΩ, max.)
(°C )
I04-4R7-3R3-_   6.4
  4.7
11
20.3
I04-100-3R3-_ 14.8
10.0
16.5
19.3
I04-220-3R3-_ 28.8
22.0
26
17.8
I04-2R2-6R0-_   3.0
  2.7
  2.2
  3.2
18.5
I04-220-6R0-_ 34.8
29.0
22.0
13
16.2
I04-4R7-8R0-_   7.2
  6.5
  5.5   4.7
  4.2
16.7
I04-100-8R0-_ 14.7
13.3
11.5 10.0
  6.5
15.3
I04-150-8R0-_ 20.7
18.5
16.0 15.0
9
15
I04-220-8R0-_ 27.5
26.0
24.0 22.0
7
13.1
I04-2R2-130-_   3.5
  2.8   2.5   2.2
  2.4
19.4
I04-100-130-_ 13.7
12.0 11.8 10.0
  2.8
10.2
I04-4R7-160-_   7.5
  6.3   5.8   4.7
2
12.1
1. Tested at 20 kHz and a Bmax of 10 Gauss.
2. Electrical specifications at 25°C.
3. Operating range: -40°C to +130°C. This is a combination of ambient plus temperature rise.
4. Meets UL 94V-0.
5. Temperature rise created by total design losses (copper loss plus core loss) at an ambient temperature of 25°C. Copper loss is calculated using the current
associated with the bold faced inductance value. Core loss assumes a output 0.5V ripple at 132kHz.
6. All inductance values assume a maximum temperature rise less than 25°C at an ambient temperature of 25°C.
6. The tolerance for no load inductance is +/-20%.
7. For mounting options, please specify H (Horizontal) or V (Vertical) at the end of the part number.
Specifications subject to change without notice.
(7/07) I04-1