English
Language : 

ACN2192A100 Datasheet, PDF (1/2 Pages) High Voltage Power Solutions, Inc. – High Voltage Power Supplies
• Cost Effective
• Metal Case NEMA 1
• Reliable Solid-State Design
• Maintanence Free
• High Load Current Alarm Contacts
• Shutdown (overload) Alarm Contacts
• HV Meter on Front Panel to Monitor Output
(Voltage & Current)
• Automatic Over-Current Shutdown and Recovery
• High Frequency Switch-Mode Design
• RoHS Versions Available
2192 Series
High Voltage Power Supplies
Input Voltage
Power
Voltages Available
Voltage Adjustment
Power
Current
Voltage Regulation
Line Regulation
Ripple
Stability
Operating Temperature
Temperature Coefficient
Storage
Humidity
Altitude
Conditions
Input
All Versions
At Max load
Output
Primary Output
Front Panel Potentiometer
Nominal Input, Max Vo
Nominal Input, Max Vo
Any Static Load, Max Vo
Over Input Range
Full Load, Max Vo
Over 8hr, 30 min warm up
Environmental
Case Temp, Full Load, Max Vo
Over the Operating Temperature
Non-Operating, Case Temp
Non-Condensing
Standard Operating Conditions
Value
120
25
-100
60% to 100%
15
0.175
<20%
<1%
<1%
<1%
0 to +60
0.06
-40 to +85
0 to 95%
0 to 10000
Units
VAC
W
kVDC max
-
W
mA
VDC
VDC
Vp-p
VDC
°C
%/°C
°C
RH
Feet
INFO@DEANTECHNOLOGY.COM
WWW.DEANTECHNOLOGY.COM
+1.972.248.7691
VERSION: 7.0
EFFECTIVE: 06 JULY 2015
PAGE: 1 OF 2