English
Language : 

HTG3400 Datasheet, PDF (1/10 Pages) Humirel – RELATIVE HUMIDITY AND TEMPERATURE MODULE
HTG3400 Series
Compliant with RoHS regulations
RELATIVE HUMIDITY AND TEMPERATURE MODULE
Based on the rugged HUMIREL humidity sensor, the HTG3400 series are dedicated humidity and temperature plug and
play transducers designed for OEM applications where reliable and accurate measurements are needed. Direct interface
with a micro-controller is made possible with the modules humidity linear frequency and direct NTC outputs. The
HTG3400 series are designed for high volume and demanding applications, where power consumption is critical.
• HTG SERIES GENERAL CHARACTERISTICS
Main Features
Suitable for small bulk assembly
Product free from Lead, Cr (6+), Cd and Hg. Compliant with RoHS
Reliability not affected by repeated condensation
Full interchangeability. Better than +/-3%RH and +/-0.25°C
Demonstrated reliability and long term stability
Humidity calibrated within +/- 3% RH @ 55% RH
Temperature measurement through NTC direct output
Ratiometric to voltage supply within the specified range
HTG3400 Series are also available with a Humidity Linear Voltage Output : HTG3500 Series (HPC123_0)
Maximum Ratings
Storage Temperature
Tstg
Supply Voltage (Peak)
Vcc
Humidity Operating Range
RH
Temperature Operating Range
Ta
Maximum Output Current (Peak) I peak
Maximum Power
Pd
Electrical Characteristics
(@T=23°C, RL>1MΩ unless otherwise noted)
- 40 to +125
20
0 to 100
-40 to +110
3
10
°C
Vdc
%RH
°C
mA
mW
100
75
50
25
0
-40
-20
OPERATING RANGE
Peak Condition
at 450g/kg
Maximum Humidity
of 250g/kg
0
20
40
60
80
100
TEMPERATURE IN °C
Humidity Measuring Range
RH
0
Relative Humidity Accuracy (10% to 95%RH)
Temperature coefficient (10°C to 50°C)
Tcc
Recovery time after 150 hours of condensation
t
Humidity hysteresis
Output impedance
Z
Sink current capability (RL_Min = 8 kOhms) (1)
I
Warm up time
tw
Constant Time (at 63% of signal) 33%RH to 75%RH (2)
τ
(1) Conditions of sink current: Vout + 0.054V (3%RH) at Vout = 0.600 V (Vout min)
(2) At 1m/s air flow
±3
-0.05
10
+/-1
150
5
100
%RH
±5
%RH
-0.1 %RH/°C
s
%RH
50
Ω
1
mA
ms
10
s
*
Nominal resistance @ 25°C
R
9.9
10
10.1
Beta value : B25/50
B
3346
3380
3414
Temperature measuring range
Nominal Resistance Tolerance at 25°C
B value tolerance
Ta
-40
85
Rn
1
B
1
Constant Time
10
* Except for low temperatures
________________________________________________________________________________________
Humirel HTG3400 Series Datasheet / HPC124 Rev A November 2007
k
K
°C
%
%
s
1