English
Language : 

HS1101LF Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – Relative Humidity Sensor
RELATIVE HUMIDITY SENSOR
HS1101LF
Meets RoHS regulations
Based on a unique capacitive cell, these relative humidity sensors are designed for high
volume, cost sensitive applications such as office automation, automotive cabin air
control, home appliances, and industrial process control systems. They are also useful
in all applications where humidity compensation is needed.
MAIN FEATURES
● Lead free components
● Full interchangeability with no calibration required in standard conditions
● Instantaneous desaturation after long periods in saturation phase
● Compatible with automatized assembly processes, including Pb free
wave soldering and reflow processes (1)
● High reliability and long term stability
● Patented solid polymer structure
● Suitable for linear voltage or frequency output circuitry
● Fast response time and very low temperature coefficient
● Part may be washed with distilled water.
● Individual marking for compliance to stringent traceability requirements
(1) soldering temperature profiles available on request / contact us at application@humirel.com
MAXIMUM RATINGS
Ratings
Symbol
Operating Temperature
Ta
Storage Temperature
Tstg
Supply Voltage (Peak)
Vs
Humidity Operating Range
RH
Value
-60 to 140
-60 to 140
10
0 to 100
Unit
°C
°C
Vac
% RH
100
90
80
70
60
50
40
30
20
10
0
-60
-40
-20
0
Operating Range
20
40
60
80
Temperature in °C
100
120
140
160
CHARACTERISTICS
Humidity sensor (Ta = 25°C, measurement frequency @ 10kHz / 1V unless otherwise noted)
Characteristics
Symbol Min. Typ. Max. Unit.
Humidity measuring range
RH
1
99
%RH
Supply voltage
Vs
10
V
Nominal capacitance @ 55% RH*
C
177
180
183
pF
Temperature coefficient
Tcc
0.01
pF/°C
Averaged Sensitivity from 33% to 75% RH
∆C /% RH
0.31
pF/% RH
Leakage current (Vcc = 5 Volts)
I
1
nA
Recovery time after 150 hours of condensation
tr
10
s
Humidity Hysteresis
+/-1
%RH
Long term stability
Time constant (33 to 80 % RH, still air @ 63%)
Deviation to typical response curve (10% to 90%) RH)
τ
+/-0.5
%RH/yr
ta
3
5
s
+/-2
%RH
*tighter specification available on request
HUMIREL HPC052 Rev.E April 2007
TECHNICAL 1 DATA
HS1101LF